alexa Correction of retention time shifts for chromatographic fingerprints of herbal medicines.
Engineering

Engineering

Journal of Biosensors & Bioelectronics

Author(s): Gong F, Liang YZ, Fung YS, Chau FT

Abstract Share this page

Abstract In this study, the combination of chemometric resolution and cubic spline data interpolation was investigated as a method to correct the retention time shifts for chromatographic fingerprints of herbal medicines obtained by high-performance liquid chromatography-diode array detection (HPLC-DAD). With the help of the resolution approaches in chemometrics, it was easy to identify the purity of chromatographic peak clusters and then resolve the two-dimensional response matrix into chromatograms and spectra of pure chemical components so as to select multiple mark compounds involved in chromatographic fingerprints. With these mark components determined, the retention time shifts of chromatographic fingerprints might be then corrected effectively. After this correction, the cubic spline interpolation technique was then used to reconstruct new chromatographic fingerprints. The results in this work showed that, the purity identification of the chromatographic peak clusters together with the resolution of overlapping peaks into pure chromatograms and spectra by means of chemometric approaches could provide the sufficient chromatographic and spectral information for selecting multiple mark compounds to correct the retention time shifts. The cubic spline data interpolation technique was user-friendly to the reconstruction of new chromatographic fingerprints with correction. The successful application to the simulated and real chromatographic fingerprints of two Cortex cinnamomi, fifty Rhizoma chuanxiong, ten Radix angelicae and seventeen Herba menthae samples from different sources demonstrated the reliability and applicability of the approach investigated in this work. Pattern recognition based on principal component analysis for identifying inhomogenity in chromatographic fingerprints from real herbal medicines could further interpret it.
This article was published in J Chromatogr A and referenced in Journal of Biosensors & Bioelectronics

Relevant Expert PPTs

Relevant Speaker PPTs

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords