Abstract Share this page

Abstract Sialic acid determination in an infant formula presents many challenges, including efficient sialic acid release from glycoconjugates, effective sample preparation, and rugged chromatography. This work compares 2 chromatographic assays developed for determination of sialic acids in infant formula. Prior to chromatography, both assays release sialic acids by acid hydrolysis and treat the hydrolysate with a subsequent anion-exchange sample preparation. Both high-performance anion-exchange chromatography with pulsed amperometric detection (HPAEC-PAD) and fluorescence ultra-high-performance liquid chromatography (UHPLC) sample analysis methods were evaluated to compare assay performance and convenience. Calibration ranges were chosen to encompass the expected amounts of 2 sialic acids in infant formula: N-acetylneuraminic acid (Neu5Ac) and N-glycolylneuraminic acid (Neu5Gc). Response was linear by either method with coefficients of determination of 1.00 by HPAEC-PAD between 5.0 and 100pmol of Neu5Ac and between 0.34 and 6.8 pmol of Neu5Gc and >0.99 by UHPLC between 5.0 and 260 pmol of Neu5Ac and between 0.20 and 9.8 pmol of Neu5Gc. Both methods had sufficient sensitivity to determine these sialic acids in infant formula. Three infant formulas were analyzed to evaluate accuracy and precision of the assays. The HPAEC-PAD assay was found to be faster overall and the UHPLC assay was more sensitive. Reaction efficiency, and therefore sensitivity, was dependent on the sample matrix. This work illustrates sample-specific complexity that must be considered in choosing an assay. Copyright © 2012 American Dairy Science Association. Published by Elsevier Inc. All rights reserved. This article was published in J Dairy Sci and referenced in Anatomy & Physiology: Current Research

Relevant Expert PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords