alexa Diagnostic performance of coronary angiography by 64-row CT.
Infectious Diseases

Infectious Diseases

Journal of AIDS & Clinical Research

Author(s): Miller JM, Rochitte CE, Dewey M, ArbabZadeh A, Niinuma H,

Abstract Share this page

Abstract BACKGROUND: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. METHODS: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50\% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. RESULTS: A total of 56\% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50\% or more according to conventional angiography revealed an AUC of 0.93 (95\% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85\% (95\% CI, 79 to 90), a specificity of 90\% (95\% CI, 83 to 94), a positive predictive value of 91\% (95\% CI, 86 to 95), and a negative predictive value of 83\% (95\% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95\% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95\% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95\% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95\% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. CONCLUSIONS: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.) 2008 Massachusetts Medical Society This article was published in N Engl J Med and referenced in Journal of AIDS & Clinical Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords