alexa Differential use of cardiac troponin T versus I in hemodialysis patients.
Clinical Sciences

Clinical Sciences

Cardiovascular Pharmacology: Open Access

Author(s): Fehr T, Knoflach A, Ammann P, Pei P, Binswanger U, Fehr T, Knoflach A, Ammann P, Pei P, Binswanger U

Abstract Share this page

Abstract BACKGROUND: Cardiac troponin T (cTnT) is frequently elevated in asymptomatic hemodialysis (HD) patients and predicts increased cardiovascular morbidity and mortality. Compared to cTnT, cardiac troponin I (cTnI) has a shorter half-life. How this influences its diagnostic reliability in chronic HD patients is only partially known. PATIENTS AND METHODS: First, in a cross-sectional study cardiac troponins were measured in 31 asymptomatic HD patients. A third-generation cTnT assay was used. The rate of false positive tests and the intraindividual variability were determined. Second, in a retrospective analysis over 12 months all acute events with clinical suspicion for acute coronary syndrome (ACS) were analysed in the same patients to determine the diagnostic power of cTnT by receiver-operating curve (ROC) plot. RESULTS: Cross-sectional study: 9 of 52 (17\%) cTnT and 0/52 cTnI (0\%) tests were positive in asymptomatic HD patients with a low intraindividual variability. Retrospective analysis: 16 acute clinical events with determination of cTnT were recorded, and in 4/16 an ACS was diagnosed. Using a cut-off level of 0.1 microg/l, the cTnT test reached a sensitivity of 100\%, a specificity of 42\%, a positive predicitive value of 36\% and a negative predictive value of 100\%, using a cut-off level of 0.2 microg/l the corresponding values were 75\%, 58\%, 38\% and 88\%. CONCLUSIONS: Cardiac TnT, but only rarely cTnI, is elevated in a significant number of asymptomatic HD patients. For diagnosis of ACS in HD patients, a combination of cTnT and cTnI may be used, since the former has higher sensitivity and the latter higher specificity. A higher threshold value for cTnT in HD patients could further increase its diagnostic accuracy.
This article was published in Clin Nephrol and referenced in Cardiovascular Pharmacology: Open Access

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords