alexa Diode laser cyclophotocoagulation: role in the management of refractory pediatric glaucomas.
Ophthalmology

Ophthalmology

Optometry: Open Access

Author(s): Kirwan JF, Shah P, Khaw PT, Kirwan JF, Shah P, Khaw PT

Abstract Share this page

Abstract PURPOSE: To report the efficacy and complications of diode laser cyclophotocoagulation (cyclodiode) in the management of refractory pediatric glaucomas. DESIGN: Noncomparative interventional case series. PARTICIPANTS: Pediatric patients with uncontrolled glaucoma. Seventy-seven eyes of 61 patients underwent cyclodiode. Mean age was 7.4 years (range, 0.4-17 years). MAIN OUTCOME MEASURES: Intraocular pressure (IOP), visual acuity, complications. RESULTS: Diagnoses included aphakic glaucoma, congenital glaucoma, juvenile chronic arthritis, aniridia, anterior segment dysgenesis, and Sturge-Weber syndrome. Sixty percent of eyes were aphakic, and 64\% had undergone at least one previous surgical procedure for glaucoma. Patients underwent a mean of 2.3 treatment sessions per eye (maximum, 8 sessions). Mean pretreatment IOP was 32.0 mmHg. After one treatment session, 62\% had a clinically useful reduction in IOP (<22 mmHg or by 30\%), but this had fallen to 37\% by 12 months. With repeat cyclodiode, 72\% had a clinically useful reduction in IOP for a year or more (mean, 8.4-month interval between treatments). Aphakic eyes had a more sustained IOP reduction (P < 0.01 log rank test). Of treatment failures, 13\% had no useful IOP response, and three eyes developed subsequent retinal detachment and loss of vision. No other eyes lost vision because of cyclodiode-related complications. In 5.5\% of the treatment sessions there was a significant posttreatment inflammatory episode. Cyclodiode treatment did not enable a reduction in the number of medications. CONCLUSIONS: With repeated treatment, cyclodiode can provide effective control of IOP. However, the success rate is lower than with adults, and younger eyes may recover from treatment more rapidly. Although response may be temporary, cyclodiode has a lower rate of severe adverse effects than surgical modalities and has roles as a temporizing measure, as an adjunct to surgery, or in managing selected patients in whom surgery is undesirable because of a high risk of surgical complications.
This article was published in Ophthalmology and referenced in Optometry: Open Access

Relevant Expert PPTs

Relevant Speaker PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords