alexa Early endosseous integration enhanced by dual acid etching of titanium: a torque removal study in the rabbit.
General Science

General Science

Journal of Biotechnology & Biomaterials

Author(s): Klokkevold PR, Johnson P, Dadgostari S, Caputo A, Davies JE,

Abstract Share this page

Abstract Textured implant surfaces are thought to enhance endosseous integration. Torque removal forces have been used as a biomechanical measure of anchorage, or endosseous integration, in which the greater forces required to remove implants may be interpreted as an increase in the strength of bony integration. The purpose of this study was to compare the torque resistance to removal of screw-shaped titanium implants having a dual acid-etched surface (Osseotite) with implants having either a machined surface, or a titanium plasma spray surface that exhibited a significantly more complex surface topography. Three custom screw-shaped implant types - machined, dual acid-etched (DAE), and titanium plasma sprayed (TPS) - were used in this study. Each implant surface was characterized by scanning electron microscopy and optical profilometry. One DAE implant was placed into each distal femur of eighteen adult New Zealand White rabbits along with one of the other implant types. Thus, each rabbit received two DAE implants and one each of the machined, or TPS, implants. All implants measured 3.25 mm in diameter x 4.00 mm in length without holes, grooves or slots to resist rotation. Eighteen rabbits were used for reverse torque measurements. Groups of six rabbits were sacrificed following one, two and three month healing periods. Implants were removed by reverse torque rotation with a digital torque-measuring device. Three implants with the machined surface preparation failed to achieve endosseous integration. All other implants were anchored by bone. Mean torque values for machined, DAE and TPS implants at one, two and three months were 6.00+/-0.64 N-cm, 9.07+/-0.67 N-cm and 6.73+/-0.95 N-cm; 21.86+/-1.37 N-cm, 27.63+/-3.41 N-cm and 27.40+/-3.89 N-cm; and 27.48+/-1.61 N-cm, 44.28+/-4.53 N-cm and 59.23+/-3.88 N-cm, respectively. Clearly, at the earliest time point the stability of DAE implants was comparable to that of TPS implants, while that of the machined implants was an order of magnitude lower. The TPS implants increased resistance to reverse torque removal over the three-month period. The results of this study confirm our previous results that demonstrated enhanced bony anchorage to dual acid-etched implants as compared to machined implants. Furthermore, the present results indicate that dual acid etching of titanium enhances early endosseous integration to a level which is comparable to that achieved by the topographically more complex TPS surfaces.
This article was published in Clin Oral Implants Res and referenced in Journal of Biotechnology & Biomaterials

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

[email protected]

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords