alexa Ecotoxicological study of Lithuanian and Estonian wastewaters: selection of the biotests, and correspondence between toxicity and chemical-based indices.
Engineering

Engineering

Journal of Civil & Environmental Engineering

Author(s): Manusadzianas L, Balkelyte L, Sadauskas K, Blinova I, Pllumaa L, , Manusadzianas L, Balkelyte L, Sadauskas K, Blinova I, Pllumaa L,

Abstract Share this page

Abstract The toxicity of industrial and urban wastewater (WW) samples collected in Lithuania and Estonia was evaluated by using a suite of biological tests comprising the Algaltoxkit F with Selenastrum capricornutum, the Charatox with Nitellopsis obtusa, Daphtoxkit F with Daphnia magna, Thamnotoxkit F with Thamnocephalus platyurus, Protoxkit F with Tetrahymena thermophila and the Microtox with Vibrio fischeri. The Charatox and Thamnotoxkit F tests showed highest relative sensitivity, responding to 80-90\% of samples, respectively, and both expressed good discrimination capacity between samples. Principal Component and pairwise correlation analysis allowed to select test-battery consisting of Charatox, Thamnotoxkit and Microtox. The WW toxicity was evaluated by means of cumulative indices such as average toxicity (AvTx) and two indices derived from the PEEP-index (Environ. Toxicol. Water Qual. 8 (1993) 115). In addition to these integrated evaluations of test-battery response, WW toxicity was evaluated according to the most sensitive test (MST) in the battery. The linear regression analysis between cumulative toxicity indices and chemical-based indices (derived from comparison of WW chemical concentrations and their respective maximum allowable concentration) revealed positive linear relationships (r(2)=0.7-0.8), while toxicity evaluation based on the MST was less positively related with chemical analysis data (r(2)=0.5-0.6). Although better coincidence between the toxicity and chemical-based assessments was achieved when information from all tests in the battery was assembled, the prediction of toxicity from chemical data was still limited. In search of suitable test-battery for the screening of certain type of WWs, a preliminary study comprising excessive suite of tests might be useful.
This article was published in Aquat Toxicol and referenced in Journal of Civil & Environmental Engineering

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords