alexa Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements.
Orthopaedics

Orthopaedics

Orthopedic & Muscular System: Current Research

Author(s): Parratte S, Pagnano MW, Trousdale RT, Berry DJ

Abstract Share this page

Abstract BACKGROUND: One long-held tenet of total knee arthroplasty is that implant durability is maximized when postoperative limb alignment is corrected to 0° ± 3° relative to the mechanical axis. Recently, substantial health-care resources have been devoted to computer navigation systems that allow surgeons to more often achieve that alignment. We hypothesized that a postoperative mechanical axis of 0° ± 3° would result in better long-term survival of total knee arthroplasty implants as compared with that in a group of outliers. METHODS: Clinical and radiographic data were reviewed retrospectively to determine the fifteen-year Kaplan-Meier survival rate following 398 primary total knee arthroplasties performed with cement in 280 patients from 1985 to 1990. Preoperatively, most knees were in varus mechanical alignment (mean and standard deviation, 6° ± 8.8° of varus [range, 30° of varus to 22° of valgus]), whereas postoperatively most knees were corrected to neutral (mean and standard deviation, 0° ± 2.8° [range, 8° of varus to 9° of valgus]). Postoperatively, we defined a mechanically aligned group of 292 knees (with a mechanical axis of 0° ± 3°) and an outlier group of 106 knees (with a mechanical axis of beyond 0° ± 3°). RESULTS: At the time of the latest follow-up, forty-five (15.4\%) of the 292 implants in the mechanically aligned group had been revised for any reason, compared with fourteen (13\%) of the 106 implants in the outlier group (p = 0.88); twenty-seven (9.2\%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, wear, or patellar problems, compared with eight (7.5\%) of the 106 implants in the outlier group (p = 0.88); and seventeen (5.8\%) of the 292 implants in the mechanically aligned group had been revised because of aseptic loosening, mechanical failure, or wear, compared with four (3.8\%) of the 106 implants in the outlier group (p = 0.49). CONCLUSIONS: A postoperative mechanical axis of 0° ± 3° did not improve the fifteen-year implant survival rate following these 398 modern total knee arthroplasties. We believe that describing alignment as a dichotomous variable (aligned versus malaligned) on the basis of a mechanical axis goal of 0° ± 3° is of little practical value for predicting the durability of modern total knee arthroplasty implants. This article was published in J Bone Joint Surg Am and referenced in Orthopedic & Muscular System: Current Research

Relevant Expert PPTs

Relevant Speaker PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri & Aquaculture Journals

Dr. Krish

agriaquaculture@omicsonline.com

1-702-714-7001Extn: 9040

Biochemistry Journals

Datta A

biochemjournals@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

chemistryjournals@omicsonline.com

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

clinicaljournals@omicsonline.com

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

engineeringjournals@omicsonline.com

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

nutritionjournals@omicsonline.com

1-702-714-7001Extn: 9042

General Science

Andrea Jason

generalscience@omicsonline.com

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

geneticsmolbio@omicsonline.com

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immunomicrobiol@omicsonline.com

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

nursinghealthcare@omicsonline.com

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

medicaljournals@omicsonline.com

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuropsychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

pharmajournals@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001Extn: 9042

 
© 2008- 2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords