alexa Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs.
Mathematics

Mathematics

Journal of Applied & Computational Mathematics

Author(s): Shivaramu

Abstract Share this page

Abstract Effective atomic numbers for photon energy- absorption (Z(PEA)eff) and photon interaction (ZPI(eff)) of human organs and tissues such as cortical bone, ovary, eye lens, testis, breast tissue, adipose tissue, lung tissue, soft tissue, soft tissue, (4-component), blood (whole), brain (grey/white matter), and skeletal muscle have been calculated by a direct method in the energy region of 1 keV to 20 MeV. The ZPEAeff and ZPIeff values steadily increase, up to 8-50 keV, and steadily decrease up to 1.25-2.0 MeV for all of the substances studied. From 2.0 MeV, the values rise with the increase in energy, up to 20 MeV. Significant differences exist between the ZPIeff and ZPEAeff in the energy region of 20-400 keV and 3-20 MeV for cortical bone; 15-150 keV for soft tissue, ovary, testis, blood, brain, lung, and skeletal muscle; 15-100 keV for breast tissue, eye lens, and soft tissue (4-component); and 10-100 keV for adipose tissue. A maximum difference of 28.37\% is observed at 100 keV for cortical bone, and 30.43\% at 40 keV for adipose tissue. For ovary, eye lens, testis, breast tissue, lung tissue, soft tissue, soft tissue (4-component), blood (whole), brain (grey/white matter), and skeletal muscle, a maximum difference of 31.74\%, 29.60\%, 31.87\%, 30.61\%, 31.47\%, 31.52\%, 29.95\%, 31.63\%, 32.36\%, and 31.42\%, respectively, is seen at 50 keV. The energy positions at which the maximum of ZPEAeff and ZPIeff occurs differ. The single effective atomic number directly obtained using the program XMuDat (Z(XMUDATTeff)) are found to be higher compared to those of ZPEAeff and ZPIeff values. The effect of absorption edge on effective atomic numbers, and its variation with photon energy and the possibility of defining 2 set values of effective atomic numbers below the absorption edges of elements present in the organs and tissues, are discussed.
This article was published in Med Dosim and referenced in Journal of Applied & Computational Mathematics

Relevant Expert PPTs

Relevant Speaker PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords