alexa Evaluation of two dose-volume histogram reduction models for the prediction of radiation pneumonitis.
Oncology

Oncology

OMICS Journal of Radiology

Author(s): Kwa SL, Theuws JC, Wagenaar A, Damen EM, Boersma LJ,

Abstract Share this page

Abstract PURPOSE: To evaluate the similarities between the mean lung dose and two dose-volume histogram (DVH) reduction techniques of 3D dose distributions of the lung. PATIENTS AND METHODS: DVHs of the lungs were calculated from 3D dose distributions of patients treated for malignant lymphoma (44), breast cancer (42) and lung cancer (20). With a DVH reduction technique, a DVH is summarized by the equivalent uniform dose (EUD), a quantity which is directly related to the normal tissue complication probability (NTCP). Two DVH reduction techniques were used. The first was based on an empirical model proposed by Kutcher et al. (Kutcher, G.J., Burman, C., Brewster, M.S., Goitein, M. and Mohan, R. Histogram reduction method for calculating complication probabilities for three-dimensional treatment planning evaluations. Int. J. Radiat. Oncol. Biol. Phys. 21: 137-146, 1991), which needs a volume exponent n. Several values for n were tested. The second technique was based on a radiobiological model, the parallel functional subunit model developed by Niemierko et al. (Niemierko, A. and Goitein, M. Modeling of normal tissue response to radiation: the critical volume model. Int. J. Radiat. Oncol. Biol. Phys. 25: 135-145, 1993) and Jackson et al. (Jackson, A., Kutcher, G.J. and Yorke, E.D. Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation. Med. Phys. 20: 613-625, 1993), for which a local dose-effect relation needed to be specified. This relation was obtained from an analysis of perfusion and ventilation SPECT data. RESULTS: It can be shown analytically that the two DVH reduction techniques are identical, if the local dose-effect relation obeys a power-law relationship in the clinical dose range. Local dose-effect relations based on perfusion and ventilation SPECT data can indeed be fitted with a power-law relationship in the range 0-80 Gy, from which values of n = 0.8-0.9 were deduced. These correspond to the commonly used value of n = 0.87 for lung tissue and yielded EUDn=0.87 values which were almost identical to the mean lung doses. For other n values, for which no experimental data are present, differences exist between EUD and mean dose values. Six patients with malignant lymphoma (6/44) and none of the breast cancer patients (0/42) developed radiation pneumonitis. These cases occurred only at high values for the mean lung dose. CONCLUSION: The two DVH reduction techniques are identical for lung and are very similar to mean dose calculations. The two techniques are also relatively similar for other model parameter values.
This article was published in Radiother Oncol and referenced in OMICS Journal of Radiology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords