alexa Fatal group C streptococcal infection due to transfusion of a bacterially contaminated pooled platelet unit despite routine bacterial culture screening.
Haematology

Haematology

Journal of Blood Disorders & Transfusion

Author(s): Lessa F, Leparc GF, Benson K, Sanderson R, Van Beneden CA,

Abstract Share this page

Abstract BACKGROUND: An elderly man with chronic myelomonocytic leukemia developed respiratory distress and died less than 48 hours after transfusion of a pool of eight whole blood-derived platelets (PLTs). Blood cultures from the recipient and cultures of remnants from the pooled PLT bag grew group C streptococci (GCS). An investigation was conducted to identify both the infection's source and the reasons for the false-negative screening result. STUDY DESIGN AND METHODS: Red blood cell (RBC) units (cocomponent from the eight donations) were traced, quarantined, and cultured. Specimens from the implicated donor were obtained. Isolates were identified and typed by 16S rRNA and pulsed-field gel electrophoresis (PFGE). The blood center screening method was reviewed. RESULTS: beta-Hemolytic GCS, cultured from 1 of 8 RBC units, linked the fatal case to a single donor. The donor's throat swab collected 20 days after donation was positive for the presence of GCS, identified as Streptococcus dysgalactiae subsp. equisimilis. Isolates from the recipient, RBC unit, residual PLTs, and donor's throat swab were indistinguishable by PFGE. The donor denied any symptoms of infection before or after donation. PLT bacterial screening at the blood center was performed using a commercially available bacterial detection system (BacT/ALERT, bioMérieux) with a threshold of 15 colony-forming units per bag. CONCLUSION: An asymptomatic donor was implicated as the source of GCS-contaminated PLTs. Current screening methods for PLTs are not sufficient to detect all bacterial contamination. Pooled PLTs are a particular challenge because the small volume of individual units places limits on culturing strategies. Improved detection of bacterial contamination of PLTs is needed. This article was published in Transfusion and referenced in Journal of Blood Disorders & Transfusion

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords