alexa Femoral fracture after harvesting of autologous bone graft using a reamer irrigator aspirator.
Surgery

Surgery

Surgery: Current Research

Author(s): Giori NJ, Beaupre GS

Abstract Share this page

Abstract A case of postoperative fracture in the donor femur after obtaining autologous bone graft with a reamer/irrigator/aspirator is presented. This procedure was successful in healing a difficult femoral nonunion, but the patient sustained a fracture of the contralateral (bone graft donor) femur 20 days after surgery. A mechanical analysis is conducted of this case and recommendations are made. Unrestricted weightbearing on a limb that has undergone reamer/irrigator/aspirator bone graft harvesting, particularly in a noncompliant patient, is probably inadvisable. If possible, one should obtain bone graft from the same limb as the fracture being treated because this will leave the patient with one unaltered limb for mobilization. This article was published in J Orthop Trauma and referenced in Surgery: Current Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

  • Rheumatology and Arthritis Surgeons Meeting
    October 2-4, 2017 Las Vegas , USA
  • 3rd International Conference on Spinal Surgery
    October 16-18, 2017, Chicago, USA
  • Global surgeons meeting on Bariatric surgery
    October 30-November 1, 2017,San Antonio,USA

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords