Abstract Share this page

Abstract A simple, rapid and fully automated flow injection method with fluorimetric detection after hydrolysis with H2SO4 in ethanolic or methanolic medium at room temperature has been developed for the determination of 1,4-benzodiazepines (oxazepam, diazepam and nitrazepam) in pharmaceutical formulations. The calibration curves are linear in the ranges (mg ml(-1)) of oxazepam (0.025-0.150), diazepam (0.010-0.125) and nitrazepam (0.010-0.150), with detection limits of 0.01, 0.005 and 0.005 mg ml(-1), respectively, and RSD (1\% (n = 10). The measurement throughput is 60 h(-1) using a 200-microl sample volume obtained by the direct dissolution of formulations in alcohol.