Abstract PURPOSE: To assess the safety, tolerability and efficacy of high-frequency periodic thalamic stimulation in inoperable mesial temporal epilepsy and the usefulness of intracranially evoked responses for assessment of anatomical uniformity of lead placement. METHODS: Four subjects were implanted with leads aimed at the anterior thalamic nuclei. Six weeks later, Soletra IPGs were activated using parameters similar to the closed-loop trial's (mean: 175 Hz; 4.1 V; 90 mus; 1 min ON, 5 min OFF). Efficacy was assessed by comparing percentage change in seizure frequency over a 6-month baseline versus a 36-month treatment period, using a within-subjects repeated measures design. Tolerability and safety were similarly monitored. Evoked responses elicited by thalamic stimulation were recorded from depth electrodes in the amygdalo-hippocampal regions and compared intra and interindividually. RESULTS: All subjects completed the study, tolerated stimulation and had no serious adverse effects. Mean reduction in seizure frequency was 75.6\% (t =-8.24; p < or = 0.01) (range: 92\% to 53\%). Quality of life improved in all. Verification of electrode placement with a software function indicated that stimulated structures were presumably, Anterior thalami, Latero-polaris, Reticulatus Polaris, Ventro-oralis Internus, and Campus Forelii. Evoked responses from stimulated sites were heterogeneous, intra and interindividually, also suggesting a lack of uniformity in lead placement. CONCLUSIONS: High-frequency, periodic, round-the-clock thalamic stimulation seems safe, well tolerated and efficacious for inoperable mesial temporal epilepsy. Identification of clinically useful parameters may be facilitated by brief closed-loop trials. Selective stimulation of a single structure may not be feasible at certain intensities, nor required for efficacy. Evoked responses may be useful for verification of uniformity of target acquisition. This article was published in Epilepsia and referenced in Journal of Neurology & Neurophysiology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords