alexa Improved analytical procedure for the measurement of captopril in human plasma by gas chromatography--mass spectrometry and its application to pharmacokinetic studies.
Medicine

Medicine

Advanced Techniques in Biology & Medicine

Author(s): Franklin ME, Addison RS, Baker PV, Hooper WD

Abstract Share this page

Abstract An enhanced, sensitive GC-MS assay is presented for the highly specific angiotensin-converting enzyme (ACE) inhibitor, captopril. This method improves previously published assays by using solid NEM as stabilizer in the collection tubes, a rapid extraction technique with dichloromethane and back-extraction into base, a commercially available internal standard (thiosalicylic acid) and a capillary GC column. Captopril and the internal standard are measured as their bis-pentafluorobenzyl derivatives. The assay was linear from 10 to 5000 ng/ml with a mean recovery following solvent extraction at 50, 200 and 1000 ng/ml of 77\%. At mean values of 45.9, 187 and 980 ng/ml inter-assay precision and accuracy were 4.0, 2.9 and 3.5\% and 8.2, 6.5 and 3.1\%, respectively. Analysis of captopril concentrations in plasma samples from 20 volunteers following oral administration of 100 mg of captopril provided the following pharmacokinetic data (mean+/-S.D.): Cmax, 1470+/-467 ng/ml; AUC(0-infinity), 1736+/-481 ng/ml.h; Tmax, 0.73 h; k(e), 0.468+/-0.122 h(-1); elimination half life, 1.58/-0.41 h.
This article was published in J Chromatogr B Biomed Sci Appl and referenced in Advanced Techniques in Biology & Medicine

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords