alexa Influence of beach chair position on cerebral oxygen saturation: a comparison of INVOS and FORE-SIGHT cerebral oximeter.
Anesthesiology

Anesthesiology

Journal of Anesthesia & Clinical Research

Author(s): Closhen D, Berres M, Werner C, Engelhard K, Schramm P

Abstract Share this page

BACKGROUND: Although beach chair position (BCP) is frequently used for shoulder surgery, a potentially detrimental influence on cerebral oxygenation is discussed. Therefore, the present study investigated changes in regional cerebral oxygen saturation (rSO2/StO2) during BCP comparing 2 different devices for near-infrared spectroscopy measurement. METHODS: Data were collected in 35 patients undergoing shoulder surgery in BCP and compared with a control group of 35 awake volunteers. The rSO2/StO2 was assessed using INVOS and FORE-SIGHT monitors. Mean arterial blood pressure (MAP), peripheral oxygen saturation (SpO2), PeCO2, FiO2, end-tidal sevoflurane concentration, and rSO2/StO2 were measured before positioning, during BCP, and in supine position after surgery. RESULTS: A decrease in rSO2/StO2 could be observed after BCP (INVOS: 76.1% supine vs. 66.7% BCP, P<0.001; FORE-SIGHT: 78.6% supine, 66.1% BCP, P<0.001), which was reversible in supine position. This decrease correlated with MAP during BCP, while in supine position no correlation was detected. In control group BCP did not influence rSO2/StO2. Changes detected with INVOS or FORE-SIGHT cerebral oximeter did not differ. CONCLUSION: BCP is associated with a decrease in rSO2/StO2 of 10% in anesthetized patients, which is reversible after repositioning. No changes occurred in supine position under general anesthesia as well as in awake subjects in BCP. This underlines the assumption that vasodilation by anesthetics in combination with BCP evoke a drop in rSO2/StO2. A strict hemodynamic management may be necessary to prevent desaturation events. Despite different technology used by the devices, the results of INVOS and FORE-SIGHT cerebral oximeters are comparable.

This article was published in J Neurosurg Anesthesiol. and referenced in Journal of Anesthesia & Clinical Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords