alexa Influence of hemolysis on routine clinical chemistry testing.
Pediatrics

Pediatrics

Journal of Neonatal Biology

Author(s): Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC

Abstract Share this page

Abstract BACKGROUND: Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of preanalytical variability, sample hemolysis can exert a strong influence on result reliability. Hemolytic samples are a rather common and unfavorable occurrence in laboratory practice, as they are often considered unsuitable for routine testing due to biological and analytical interference. However, definitive indications on the analytical and clinical management of hemolyzed specimens are currently lacking. Therefore, the present investigation evaluated the influence of in vitro blood cell lysis on routine clinical chemistry testing. METHODS: Nine aliquots, prepared by serial dilutions of homologous hemolyzed samples collected from 12 different subjects and containing a final concentration of serum hemoglobin ranging from 0 to 20.6 g/L, were tested for the most common clinical chemistry analytes. Lysis was achieved by subjecting whole blood to an overnight freeze-thaw cycle. RESULTS: Hemolysis interference appeared to be approximately linearly dependent on the final concentration of blood-cell lysate in the specimen. This generated a consistent trend towards overestimation of alanine aminotransferase (ALT), aspartate aminotransferase (AST), creatinine, creatine kinase (CK), iron, lactate dehydrogenase (LDH), lipase, magnesium, phosphorus, potassium and urea, whereas mean values of albumin, alkaline phosphatase (ALP), chloride, gamma-glutamyltransferase (GGT), glucose and sodium were substantially decreased. Clinically meaningful variations of AST, chloride, LDH, potassium and sodium were observed in specimens displaying mild or almost undetectable hemolysis by visual inspection (serum hemoglobin < 0.6 g/L). The rather heterogeneous and unpredictable response to hemolysis observed for several parameters prevented the adoption of reliable statistic corrective measures for results on the basis of the degree of hemolysis. CONCLUSION: If hemolysis and blood cell lysis result from an in vitro cause, we suggest that the most convenient corrective solution might be quantification of free hemoglobin, alerting the clinicians and sample recollection. This article was published in Clin Chem Lab Med and referenced in Journal of Neonatal Biology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

  • 29th World Neonatal Nursing and Maternal Healthcare Congress
    August 28-30, 2017 Philadelphia, Pennsylvania, USA
  • 2nd International Conference on Pediatric Neurology
    August 31-September 01, 2017 Prague, Czech Republic
  • 10th World Pediatric Congress
    September 28-29, 2017 Dubai, UAE
  • Infancy, Child Nutrition & Development (ICND)
    October 16-18, 2017 (20 Forums, 3 Days- 1 Event) New York, USA
  • 20th International Conference on Neonatology and Perinatology
    December 04-06, 2017 Madrid, Spain

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords