alexa Long-term durability and functional outcomes among patients with artificial urinary sphincters: a 10-year retrospective review from the University of Michigan
Surgery

Surgery

Medical & Surgical Urology

Author(s): Kim SP, Latini JM

Abstract Share this page

PURPOSE: The artificial urinary sphincter continues to be one of the most effective and commonly used surgical treatments for severe urinary incontinence. The long-term durability and functional outcome remains unclear. This study sought to report the artificial urinary sphincter complication rates, associated risk factors with complications, and long-term quality of life and durability. MATERIALS AND METHODS: This single institution study reports the outcomes of 124 consecutive index cases of artificial urinary sphincter from 1996 to 2006 for complications (infection, erosion, and mechanical failure). Bivariate statistics and multivariable logistic models were used to identify patient and artificial urinary sphincter characteristics associated with complications. Functional outcomes and long-term durability were assessed using a cross sectional analysis of a validated health related quality of life survey and a product limit estimates, respectively. RESULTS: Among the 124 male patients median followup was 6.8 years. The overall complication rate for patients undergoing an artificial urinary sphincter was 37.0%, with mechanical failure the most common cause (29), followed by erosion (10) and then infection (7). Significant differences between complications and specific patient and artificial urinary sphincter characteristics risk factors were not found. Functional outcomes appeared stable with similar mild-moderate urinary incontinence severity and 0 to 1 daily pad use at intervals of 0 to 4 years, 4 to 8 years and more than 8 years. Long-term durability was notable with 36% having complications (requiring surgical revision or removal) within 10 years and most events occurring within the first 48 months. CONCLUSIONS: Long-term durability and functional outcomes are achievable for the AMS 800, but there are appreciable complication rates for erosion, mechanical failure and infection in the first 48 months from implantation.

This article was published in J Urol and referenced in Medical & Surgical Urology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords