alexa Measurement of the Pressure Applied During Motion Palpation and Reliability for Cervical Spine Rotation
Neurology

Neurology

Journal of Spine

Author(s): Justin Marcotte, Martin C Normand, Pierre Black

Abstract Share this page

Objective: 
To measure the pressure applied during motion palpation for cervical spine rotation and to verify its effect on reliability when the kinematics of the test are standardized.
Methods: The pressure of palpation used during the test of cervical spine rotation was measured by means of flexible and extra-fine pressure sensors linked to an electronic interface. Seven pressure measurements (left rotation from C1 to C7) for each of 24 examiners were taken. In addition, the examiners were asked to detect the presence of intervertebral fixation while palpating.
Results: Pressure of palpation varied from 4.0 to 41.0 N/cm2 among the examiners. Standardization of the kinematics of the test establishes a strong reliability of identifying a fixation (κ varying from 0.701 to 0.748). Conclusions: The pressure applied during motion palpation for cervical spine rotation is light to moderate. It can vary tenfold (4-41 N/cm2) and remain reliable for identifying a fixation as long as the kinematics of the test are standardized.

This article was published in J Manipulative Physiol Ther and referenced in Journal of Spine

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords