alexa Misclassification and discordance of measured blood pressure from patient's true blood pressure in current clinical practice: a clinical trial simulation case study.
Medicine

Medicine

Journal of Gerontology & Geriatric Research

Author(s): Jin Y, Bies R, Gastonguay MR, Stockbridge N, Gobburu J,

Abstract Share this page

Abstract Treatment decisions for hypertension using sphygmomanometer based measurements and the current clinical practice paradigm do not account for the timing of blood pressure (BP) measurement. This study aimed to evaluate the clinical implications of discordance between measured and true BP, to quantify BP misclassification rate at a typical clinical visit in current clinical practice, and to propose a BP calibration system to decrease the impact of timing of BP measurement. A clinical trial simulation case study was performed using an in silico Monte Carlo Simulation approach. The time-courses of BPs with and without an antihypertensive treatment effect were simulated from a baseline BP model combined with an antihypertensive PK/PD model. Virtual subject characteristics were sampled from the FDA internal database. The baseline BP model was qualified using observed 24 h ambulatory BP monitoring (ABPM) data from 225 subjects by a visual predictive check as well as a global sensitivity analysis. First of all, our results showed that the measured cuff BP in current typical clinical practice deviated from the true values. (1) Cuff BP deviated from the true values by more than 5 mmHg in 57 \% (95 \% CI: 54-61 \%) of patients and more than 10 mmHg in 26 \% (95 \% CI: 22-32 \%) of patients respectively. (2) These discordances were reduced to 28 \% (deviation ≥ 5 mmHg, 95 \% CI: 18-40 \%) and 9 \% (deviation ≥ 10 mmHg, 95 \% CI: 4-18\%) of patients assuming perfect sphygmomanometer measurement and thus represent the contribution of ignoring the daily circadian rhythm of BP. Secondly, our results showed 23-32 \% of patients were misclassified to an incorrect BP category for a casual clinical visit based on JNC 7 guideline. In addition, the accuracy of the measured cuff BP varied by time of clinic visit. Specifically, 11:00 AM to 3:00 PM was identified to be the better time frame, while times before 9:00 AM were the worst time frame. Therefore, clinic visit time may need to be adjusted accordingly. Finally, we proposed an easy BP calibration method for clinic use to adjust for time of day differences due to circadian variability in case that the desirable clinic visit time cannot be tailored for practical reasons. This article was published in J Pharmacokinet Pharmacodyn and referenced in Journal of Gerontology & Geriatric Research

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords