alexa Multisite analytic performance studies of a real-time polymerase chain reaction assay for the detection of BRAF V600E mutations in formalin-fixed, paraffin-embedded tissue specimens of malignant melanoma.
Genetics & Molecular Biology

Genetics & Molecular Biology

Journal of Molecular Biomarkers & Diagnosis

Author(s): Anderson S, Bloom KJ, Vallera DU, Rueschoff J, Meldrum C,

Abstract Share this page

Abstract CONTEXT: A polymerase chain reaction-based companion diagnostic (cobas 4800 BRAF V600 Mutation Test) was recently approved by the US Food and Drug Administration to select patients with BRAF-mutant metastatic melanoma for treatment with the BRAF inhibitor vemurafenib. OBJECTIVES: (1) To compare the analytic performance of the cobas test to Sanger sequencing by using screening specimens from phase II and phase III trials of vemurafenib, and (2) to assess the reproducibility of the cobas test at different testing sites. DESIGN: Specimens from 477 patients were used to determine positive and negative percent agreements between the cobas test and Sanger sequencing for detecting V600E (1799T>A) mutations. Specimens were evaluated with a massively parallel pyrosequencing method (454) to resolve discordances between polymerase chain reaction and Sanger results. Reproducibility of the cobas test was assessed at 3 sites by using 3 reagent lots and an 8-member panel of melanoma samples. RESULTS: A valid cobas result was obtained for all eligible patients. Sanger sequencing had a failure rate of 9.2\% (44 of 477). For the remaining 433 specimens, positive percent agreement was 96.4\% (215 of 223) and negative percent agreement, 80\% (168 of 210). Among 42 cobas mutation-positive/Sanger V600E-negative specimens, 17 were V600E positive and 24 were V600K positive by 454. The cobas test detected 70\% of V600K mutations. In the reproducibility study, a correct interpretation was made for 100\% of wild-type specimens and specimens with greater than 5\% mutant alleles; V600E mutations were detected in 90\% of specimens with less than 5\% mutant alleles. CONCLUSIONS: The cobas test (1) had a lower assay failure rate than that of Sanger, (2) was more sensitive in detecting V600E mutations, (3) detected most V600K mutations, and (4) was highly reproducible. This article was published in Arch Pathol Lab Med and referenced in Journal of Molecular Biomarkers & Diagnosis

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

  • 9th International Conference and Expo on Molecular & Cancer Biomarkers
    August 23-24, 2017 Birmingham, UK
  • 2nd International Conference on Medical Imaging and Diagnosis
    London, UK
  • 22nd International Conference on Cancer Drugs and Therapeutics
    Paris, France
  • International Conference on Oncology Nursing and Cancer Care
    Singapore City, Singapore
  • World Summit on Cell Signalling and Cancer Therapy
    Toronto, Canada
  • International Conference on Radiology and Imaging
    New York, USA

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords