alexa New formula for calculating intraocular lens power after laser in situ keratomileusis.
Ophthalmology

Ophthalmology

Journal of Clinical & Experimental Ophthalmology

Author(s): Jarade EF, Tabbara KF

Abstract Share this page

Abstract PURPOSE: To assess the validity and accuracy of a proposed formula for keratometry (K) readings after laser in situ keratomileusis (LASIK). SETTING: The Eye Center and the Eye Foundation for Research, Riyadh, Saudi Arabia. METHOD: This studied comprised 34 eyes that had LASIK surgery. Refraction and an automated K-reading (auto-K) were performed preoperatively. Refraction, auto-K, and K-reading assessment by the clinical history method and the proposed formula were performed 4 to 12 weeks postoperatively. The proposed formula is K(postop) = K(preop) - [(N(c) - 1) x (R(a-postop) - R(a-preop))/(R(a-postop) x R(a-preop))], where K(postop) is the K-reading after LASIK, K(preop) is the K-reading before LASIK, N(c) is the index of refraction of the cornea (1.376), R(a-postop) is the radius of curvature of the anterior corneal surface after LASIK, and R(a-preop) is the radius of curvature of the anterior corneal surface before LASIK. RESULTS: Twenty patients (10 men, 10 women) were included in the study. The mean age of the patients was 30.58 years +/- 17.68 (SD) (range 18 to 44 years). Preoperatively, the mean spherical equivalent (SE) was -4.99 +/- 2.82 diopters (D) (range -1.12 to -15.00 D), the mean R(a) was 7.76 +/- 0.32 mm (range 7.33 to 8.50 mm), and the mean auto-K reading was 43.45 +/- 1.73 D (range 39.62 to 46.00 D). Postoperatively, the mean SE was +0.02 +/- 0.63 D (range -2.75 to +1.00 D), the mean R(a) was 8.63 +/- 0.53 mm (range 7.80 to 9.92 mm), and the mean K-reading assessed by auto-K, clinical history method, and the proposed formula was 39.17 +/- 2.35 D (range 34.00 to 43.25 D), 38.79 +/- 2.52 D (range 33.1 to 42.78 D), and 38.69 +/- 2.51 D (range 33.1 to 43.0 D), respectively. The results obtained by the proposed formula were similar to those obtained by the clinical history method (P =.098). Auto-K readings significantly overestimated the K-values (P<.0001) when compared to the proposed formula and clinical history method. CONCLUSION: The proposed formula was simple, objective, not dependent on refraction, and as accurate as the clinical history method in determining K-readings after LASIK. This article was published in J Cataract Refract Surg and referenced in Journal of Clinical & Experimental Ophthalmology

Relevant Expert PPTs

Relevant Speaker PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]line.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords