Abstract PURPOSE: To perform a preliminary evaluation of the image quality of pediatric technetium 99m ((99m)Tc) methylene diphosphonate (MDP) bone single photon emission computed tomography (SPECT) by using iterative reconstruction-ordered subset expectation maximization with three-dimensional resolution recovery (OSEM-3D)-and to assess whether any improvements with use of this technique could lead to a reduction in patient dose or a shortening in imaging time. MATERIALS AND METHODS: Institutional advisory board approval was obtained for this investigation. Fifty (99m)Tc-MDP SPECT studies of the spine were evaluated (36 female and 14 male patients; mean age, 15.5 years). Each study was acquired by using a dual-detector camera, with each detector rotating 360°. By using filtered back projection (FBP) and OSEM-3D, images were reconstructed from data generated by both detectors. Likewise, OSEM-3D was used to reconstruct data from a single detector simulating half the administered radiopharmaceutical activity. Two nuclear medicine physicians, blinded to the patient data, reviewed the images for image quality in four different categories by using a four-point scale: artifacts (category 1), lesions (category 2), noise (category 3), and image sharpness (category 4). RESULTS: Compared with FBP, images reconstructed by using OSEM-3D with one or two detectors showed significant improvement in image quality with regard to lesion detection, noise level, and image sharpness (P < .02, .01, and .001, respectively). With OSEM-3D, no significant differences were observed when either one or two detectors were used. CONCLUSION: Improved image quality of skeletal SPECT with either a 50\% reduction in radiation dose or a 50\% reduction in acquisition time or combination of the two can be achieved by using OSEM-3D. © RSNA, 2010. This article was published in Radiology and referenced in Journal of Clinical & Experimental Cardiology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords