alexa Prospective evaluation of visual acuity assessment: a comparison of snellen versus ETDRS charts in clinical practice (An AOS Thesis).
Ophthalmology

Ophthalmology

Optometry: Open Access

Author(s): Kaiser PK, Kaiser PK

Abstract Share this page

Abstract PURPOSE: THE PURPOSE OF THIS STUDY WAS TWOFOLD: first, to prospectively compare visual acuity (VA) scores obtained with Snellen charts versus Early Treatment Diabetic Retinopathy Study (ETDRS) charts in a "real world" retinal practice, and second, to see if there was a difference in visual acuity measurements obtained with ETDRS charts starting at 4 or 2 meters. METHODS: Prospective, consecutive evaluation of patients who underwent best-corrected visual acuity testing of their right eye performed at a single seating by the same experienced, certified vision examiner in the same room with standardized low light conditions using a projected Snellen chart at 20 feet, and two different back-illuminated ETDRS charts placed 4 and 2 meters from the patient. RESULTS: One hundred sixty-three eyes were included in the study. The mean Snellen VA was 0.67 logMAR (20/94), ETDRS VA at 4 meters was 0.54 logMAR (~20/69), and ETDRS VA at 2 meters was 0.51 logMAR (~20/65). The mean difference was 6.5 letters better on the ETDRS chart (P=.000000001). As the VA worsened, there was increased variability between the charts and the mean discrepancy between charts also increased. Subgroup analysis revealed the greatest difference between charts was in the poor vision subgroup (<20/200) with a difference of 0.2 logMAR (10 letters; P=.0000002). Patients with exudative age-related macular degeneration (AMD) had the greatest disparity on vision testing, but patients with dry AMD and diabetic retinopathy also exhibited significant differences. CONCLUSIONS: Visual acuity scores were significantly better on ETDRS charts compared to Snellen charts. The difference was greatest with poor visual acuity (<20/200) and in patients with exudative AMD. Thus, caution should be exercised when comparing data using the different charts.
This article was published in Trans Am Ophthalmol Soc and referenced in Optometry: Open Access

Relevant Expert PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

agrifoodaquavet@omicsonline.com

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

clinical_biochem@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

chemicaleng_chemistry@omicsonline.com

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

environmentalsci@omicsonline.com

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

engineering@omicsonline.com

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

generalsci_healthcare@omicsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

genetics_molbio@omicsonline.com

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immuno_microbio@omicsonline.com

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

omics@omicsonline.com

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

mathematics_physics@omicsonline.com

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

medical@omicsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuro_psychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

pharma@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version