alexa Radiation doses received in the UK Breast Screening Programme in 2001 and 2002.
Oncology

Oncology

OMICS Journal of Radiology

Author(s): Young KC, Burch A, Oduko JM

Abstract Share this page

Abstract The mean glandular doses (MGD) to samples of women attending for mammographic screening are measured routinely at screening centres in the UK Breast Screening Programme (NHSBSP). This paper reviews a large representative sample of dose measurements collected during screening in the NHSBSP in 2001 and 2002 for 53 218 films, using 290 X-ray sets, for 16 505 women. The average MGD was 2.23 mGy per oblique film and 1.96 mGy per craniocaudal film; similar to those found previously in the NHSBSP for the years 1997 and 1998. Increasing use of sophisticated units with automatic beam quality selection has reduced the radiation dose received by large breasts, with only 2\% of oblique mammograms having doses in excess of 5 mGy. The increasing use of large format film has also reduced the doses to this sub-group. However the total dose per woman has increased due to the introduction of two view screening at every visit. The MGD to the standard breast was found to vary from 0.76 mGy to 2.29 mGy, with 97\% of units below the recommended upper limit of 2 mGy, illustrating the benefit of strict quality control. A reduction in dose of 3\% was observed between the age bands 50-54 years and 60-64 years. This study has confirmed that the proposed national diagnostic reference level (NDRL) of 3.5 mGy for 55 mm thick breasts is an appropriate value to identify systems giving unusually high doses, with just 3.5\% of systems exceeding this level. In most cases these higher doses were explained by the design of one particular make of X-ray set and its mode of operation. Average doses for oblique views of average sized breasts were fairly well correlated with the dose to the standard breast, and typically 42\% higher. This highlights the need for a revised definition of the standard breast used in the UK to better reflect the exposure factors and doses received in clinical practice. This article was published in Br J Radiol and referenced in OMICS Journal of Radiology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords