alexa Radiofrequency (RF) coil impacts the value and reproducibility of cartilage spin-spin (T2) relaxation time measurements.
Genetics & Molecular Biology

Genetics & Molecular Biology

Journal of Stem Cell Research & Therapy

Author(s): Dardzinski BJ, Schneider E

Abstract Share this page

Abstract INTRODUCTION: T2 (spin-spin) relaxation time is frequently used for compositional assessment of articular cartilage. However little is known about the influence of magnetic resonance (MR) system components on these measurements. The reproducibility and range of cartilage T2 values were evaluated using different extremity radiofrequency (RF) coils with potential differences in flip angle uniformity and signal-to-noise ratio (SNR). METHOD: Ten knees underwent 3 T MR exams using RF coils with different SNR: quadrature transmit/receive (QTR); quadrature transmit/eight-channel phased-array receive (QT8PAR). Each knee was scanned twice per coil (four exams total). T2 values were calculated for the central medial and lateral femoral (cMF, cLF) and medial and lateral tibial (MT, LT) cartilage. RESULTS: The flip angle varied across a central 40 mm diameter region-of-interest of each coil by <1.5\%. However SNR was significantly higher using QT8PAR than QTR (P < 0.001). T2 values for cMF (50.7 msec/45.9 msec) and MT (48.2 msec/41.6 msec) were significantly longer with QT8PAR than QTR (P < 0.05). T2 reproducibility was improved using QT8PAR for cMF and cLF (4.8\%/5.8\% and 4.1\%/6.5\%; P < 0.001), similar for LT (3.8\%/3.6\%; P = 1.0), and worse for MT (3.7\%/3.3\%; P < 0.001). T2 varied spatially, with cLF having the longest (52.0 msec) and the LT having the shortest (40.6 msec) values. All deep cartilage had significantly longer, and less variable, T2 values using QT8PAR (higher SNR; P < 0.03). CONCLUSIONS: SNR varied spatially (significant) depending upon coil, but refocusing flip angle only slightly. With higher SNR, significantly longer T2 values were measured for deep (all plates) and global (MT, cMF) cartilage. T2 values varied by depth and plate, in agreement with prior studies. Copyright © 2013 Osteoarthritis Research Society International. All rights reserved.
This article was published in Osteoarthritis Cartilage and referenced in Journal of Stem Cell Research & Therapy

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords