alexa Radiographic evaluation of surgical clips is better than ultrasound for defining the lumpectomy cavity in breast boost treatment planning: a prospective clinical study.
Oncology

Oncology

Journal of Nuclear Medicine & Radiation Therapy

Author(s): Rabinovitch R, Finlayson C, Pan Z, Lewin J, Humphries S,

Abstract Share this page

Abstract PURPOSE: Breast radiotherapy (BrRT) often includes a "boost" to the lumpectomy bed. Selection of an appropriate electron energy and field size is based upon the dimensions and location of the surgical cavity. This study was performed to confirm our impression that ultrasound (US) inadequately defines the volume at risk compared to radiographic evaluation of surgical clips placed within the operative bed at the time of lumpectomy. METHODS AND MATERIALS Twenty-nine women treated with BrRT at our institution between 1996-1998 were prospectively identified as having surgical clips within the lumpectomy cavity. These patients underwent both US evaluation and radiographic evaluation of the clips to independently define two sets of transverse (T), longitudinal (L), and depth (D) measurements for each cavity. Volumes (V) were calculated for each method, assuming the cavity to be a box (V = T x L x D). Twenty-one women began BrRT following a median postoperative interval of 6 weeks (Group A), and 8 after 24 weeks (Group B) due to delivery of systemic therapy. RESULTS: Dimensions derived by US were smaller than the clip method in 22/29 of T, 25/29 of L, and 23/29 of D, or 80\% of all linear measurements. A paired t-test demonstrated the difference between the methods to be statistically significant: T: p = 0.0004; L: p = 0.0001; D: p = 0.0004; and V: p = 0.0001. This underestimation by US did not fit any predictable pattern. Although the mean difference between methods (clips - US) was only 1.3, 1.9, and 1.1 cm for T, L, and D, respectively, differences ranged up to 5. 7, 9.2, and 5.5 cm for T, L, and D. The bias toward underestimation of V by US was significantly greater for Group B than Group A (p = 0. 03). CONCLUSIONS: US significantly underestimates all three dimensions of the lumpectomy cavity and hence the volume at risk compared to radiographic evaluation of surgical clips. Breast-conserving surgery should include placement of clips at the margins of the lumpectomy cavity (superior, inferior, medial, lateral, and posterior) to aid in radiotherapy treatment planning. US should not be utilized to guide the design of the boost field as it will result in inappropriate selection of lower electron energies and smaller field sizes (geographical miss), particularly among patients who receive chemotherapy prior to breast radiotherapy.
This article was published in Int J Radiat Oncol Biol Phys and referenced in Journal of Nuclear Medicine & Radiation Therapy

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords