alexa Reaction time in automated kinetic perimetry: effects of stimulus luminance, eccentricity, and movement direction.
Ophthalmology

Ophthalmology

Journal of Clinical & Experimental Ophthalmology

Author(s): Schiefer U, Strasburger H, Becker ST, Vonthein R, Schiller J,

Abstract Share this page

Abstract PURPOSE: To determine the effects of stimulus eccentricity and luminance level on the reaction time (RT) of young normal volunteers during automated kinetic campimetry. METHODS: We used a specially designed video-campimetric device equipped with a continuous infrared (IR) pupillographic fixation control (Tübingen Computer Campimeter) and recorded reaction times upon presenting horizontally moving small circular stimuli (size 26'; constant angular velocity 2 degrees /s) starting at 16 locations within the central 30 degrees -radius of the visual field. Two different levels of stimulus luminance were used (41.6 cd/m(2) and 110 cd/m(2)), while background luminance was 10 cd/m(2). Each stimulus was presented a total of six times in a randomized order. Subjects were 12 healthy young individuals (aged 21-30 years) with normal ophthalmic examinations. An analysis of variance (ANOVA) was performed on the data. RESULTS: RTs showed considerable inter- and intra-individual variation with individual least squares means (LSM, fitted values of a linear model) ranging from 305 to 454 ms, and residual standard deviation (R.S.D.) 66 ms. Reaction times did not differ significantly as a function of stimulus direction (P>0.6). Higher luminance levels produced significantly reduced reaction times for all stimulus locations and directions (mean reduction: 16 ms; P<0.0001). Reaction times increased with increasing eccentricity, in the mean by 1.8 ms per degree of visual angle, from 365+/-4 ms (S.E.M.) foveally, to 407+/-2 ms at 30 degrees eccentricity; (P<0.0001). CONCLUSIONS: Automated kinetic perimetry should be designed to cope with significant, variable interindividual response characteristics. Other stimulus related factors, such as eccentricity or luminance level, have a significant but comparatively small effect on reaction time within the central 30 degrees -radius visual field in healthy young individuals.
This article was published in Vision Res and referenced in Journal of Clinical & Experimental Ophthalmology

Relevant Expert PPTs

Relevant Speaker PPTs

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords