alexa Reliability of near-infrared angiography and micro-Doppler sonography for evaluating microvascular anastomoses.
Microbiology

Microbiology

Journal of Microbial & Biochemical Technology

Author(s): Mcke T, Wolff KD, Wagenpfeil S, Hlzle F, Scholz M

Abstract Share this page

Abstract BACKGROUND: Intraoperative fluorescence angiography has been reported to be a promising method, with rapid and high-quality image production at low cost when used for the detection of microvascular complications. The purpose of this study was to evaluate the reliability of intraoperative near-infrared indocyanine green angiography compared with microvascular Doppler testing in a standardized model in the rat with different vessel patencies. METHODS: The carotid, aorta, and femoral vessels of 23 Wistar rats were used. Indocyanine green angiography and microvascular Doppler sonographic testing were performed to assess microanastomosis with a vessel patency randomly narrowed at the anastomosis to an outer patency of 100, 75, 50, 25, and 0 percent. RESULTS: A total of 424 investigations were performed for 68 anastomoses, including both indocyanine green videoangiographic and microvascular Doppler sonographic examinations. The overall sensitivity and specificity of the microvascular Doppler sonographic testing at different degrees of stenoses were 100 and 86.9 percent, respectively. The positive predictive value for all observations was 95.8 percent, and the corresponding negative predictive value was 100 percent. Indocyanine green angiography revealed an overall sensitivity of 95.3 percent and a specificity of 100 percent. The positive predictive value for these observations was 100 percent, and the negative predictive value was 84 percent. CONCLUSIONS: Indocyanine green angiography and microvascular Doppler sonography are quick and reliable methods for assessing blood flow in vessels in the laboratory model. The combined use of indocyanine green angiography and microvascular Doppler sonography can increase the accuracy of assessment of microvascular anastomoses intraoperatively. Indocyanine green can be used first, but followed by the microvascular Doppler in cases of a negative result to maximize accuracy. This article was published in Plast Reconstr Surg and referenced in Journal of Microbial & Biochemical Technology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords