alexa Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer.
Pharmaceutical Sciences

Pharmaceutical Sciences

Journal of Bioequivalence & Bioavailability

Author(s): Fiorino C, Reni M, Bolognesi A, Bonini A, Cattaneo GM,

Abstract Share this page

Abstract BACKGROUND: Conformal radiotherapy requires reduced margins around the clinical target volume (CTV) with respect to traditional radiotherapy techniques. Therefore, high set-up accuracy and reproducibility are mandatory. PURPOSE: To investigate the effectiveness of two different immobilization techniques during conformal radiotherapy of prostate cancer with small fields. MATERIALS AND METHODS: 52 patients with prostate cancer were treated by conformal three- or four-field techniques with radical or adjuvant intent between November 1996 and March 1998. In total, 539 portal images were collected on a weekly basis for at least the first 4 weeks of the treatment on lateral and anterior 18 MV X-ray fields. The average number of sessions monitored per patient was 5.7 (range 4-10). All patients were immobilized with an alpha-cradle system; 25 of them were immobilized at the pelvis level (group A) and the remaining 27 patients were immobilized in the legs (group B). The shifts with respect to the simulation condition were assessed by measuring the distances between the same bony landmarks and the field edges. The global distributions of cranio-caudal (CC), posterior-anterior (PA) and left-right (LR) shifts were considered; for each patient random and systematic error components were assessed by following the procedure suggested by Bijhold et al. (Bijhold J, Lebesque JV, Hart AAM, Vijlbrief RE. Maximising set-up accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 1992;24:261-271). For each patient the average isocentre (3D) shift was assessed as the quadratic sum of the average shifts in the three directions. RESULTS: Group B showed a better accuracy and reproducibility than group A for PA shifts (2.6 versus 4.4 mm, 1 SD), LR shifts (2.4 versus 3.6 mm, 1 SD) and CC shifts (2.7 versus 3.3 mm, 1 SD). Furthermore, group B showed a rate of large PA shifts (>5 mm) equal to 4.4\% with respect to the 21.6\% of group A (P<0.0001). This value was also better than the corresponding value found in a previously investigated group of 21 non-immobilized patients (Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis of the conformal radiotherapy of prostate cancer: comparison between two different institutions and treatment techniques (abstract). Radiother. Oncol. 1997;43(Suppl. 2):S16, 16.8\%, P = 0.001). For both groups there was no clear prevalence of one component (systematic or random) with respect to the other. The average isocentre shifts (averaged on all patients) were 3.0 mm (+/-1.4 mm, 1 SD) for group B and 5.0 mm (+/-2.8 mm, 1 SD) for group A against a value of 4.4 mm (+/-2.4 mm, 1 SD) for the previously investigated non-immobilized patient group. CONCLUSIONS: Immobilization of the legs with an alpha-cradle system seems to improve both the accuracy and reproducibility of the positioning of patients treated for prostate cancer with respect to alpha-cradle pelvic-abdomen immobilization. Based on these data, we decided to use the legs immobilization system and to reduce the margin around the CTV (from 10 to 8 mm) in the PA direction.
This article was published in Radiother Oncol and referenced in Journal of Bioequivalence & Bioavailability

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords