alexa Short-term clinical comparison of two dual-disinfection multipurpose disinfecting solutions.
Pharmaceutical Sciences

Pharmaceutical Sciences

Journal of Clinical & Experimental Pharmacology

Author(s): Tilia D, Lazon de la Jara P, Weng R, Naduvilath T, Willcox MD

Abstract Share this page

Abstract OBJECTIVE: To compare the short-term clinical performance of two dual-disinfectant multipurpose disinfecting solutions (MPDS) when used in conjunction with two silicone hydrogel contact lenses. METHODS: Participants wore galyfilcon A and balafilcon A lenses, randomly allocated one type to each eye. Multipurpose disinfecting solutions were double-masked and allocated using a randomized crossover design. Lenses were presoaked overnight in the allocated MPDS, containing either polyquaternium-1/alexidine dihydrochloride (PQ-alexidine) or polyquaternium-1/myristamidopropyl dimethylamine (PQ-MAPDA). Lenses were worn daily for 4 days and disinfected with the same MPDS in which they had been soaked. Clinical assessments occurred immediately after insertion, 2 hours after insertion, and after 2 hours of wear on day 4. Subjective ratings were collected at each assessment and after 6 hours of wear on days 1 to 3. Linear mixed models were used for statistical analysis. RESULTS: Solution-induced corneal staining (SICS) incidence was significantly different between MPDS lens combinations (P=0.01) with PQ-MAPDA-balafilcon A showing the highest incidence (27.8\%). The incidence of SICS was significantly higher when balafilcon A lenses were worn compared with galyfilcon A (19.4\% vs. 2.8\%; P=0.04). There was no significant difference in SICS incidence between MPDS (PQ-alexidine=5.6\%, PQ-MAPDA=16.7\%; P=0.08). Polyquaternium-1/alexidine dihydrochloride was associated with significantly fewer symptoms of burning/stinging (9.7±0.6 vs. 9.1±2.2; P=0.03) and self-assessed redness (9.8±0.5 vs. 9.2±1.9; P=0.03) on initial lens insertion. There were no significant differences between MPDS for comfort ratings (P>0.05). CONCLUSION: These short-term clinical results provide an initial indication that PQ-alexidine is associated with fewer symptoms on insertion but no significant difference in ocular comfort compared with PQ-MAPDA. Longer studies are required to provide further evidence. This article was published in Eye Contact Lens and referenced in Journal of Clinical & Experimental Pharmacology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords