alexa Short-term clinical comparison of two dual-disinfection multipurpose disinfecting solutions.
Pharmaceutical Sciences

Pharmaceutical Sciences

Journal of Clinical & Experimental Pharmacology

Author(s): Tilia D, Lazon de la Jara P, Weng R, Naduvilath T, Willcox MD, Tilia D, Lazon de la Jara P, Weng R, Naduvilath T, Willcox MD

Abstract Share this page

Abstract OBJECTIVE: To compare the short-term clinical performance of two dual-disinfectant multipurpose disinfecting solutions (MPDS) when used in conjunction with two silicone hydrogel contact lenses. METHODS: Participants wore galyfilcon A and balafilcon A lenses, randomly allocated one type to each eye. Multipurpose disinfecting solutions were double-masked and allocated using a randomized crossover design. Lenses were presoaked overnight in the allocated MPDS, containing either polyquaternium-1/alexidine dihydrochloride (PQ-alexidine) or polyquaternium-1/myristamidopropyl dimethylamine (PQ-MAPDA). Lenses were worn daily for 4 days and disinfected with the same MPDS in which they had been soaked. Clinical assessments occurred immediately after insertion, 2 hours after insertion, and after 2 hours of wear on day 4. Subjective ratings were collected at each assessment and after 6 hours of wear on days 1 to 3. Linear mixed models were used for statistical analysis. RESULTS: Solution-induced corneal staining (SICS) incidence was significantly different between MPDS lens combinations (P=0.01) with PQ-MAPDA-balafilcon A showing the highest incidence (27.8\%). The incidence of SICS was significantly higher when balafilcon A lenses were worn compared with galyfilcon A (19.4\% vs. 2.8\%; P=0.04). There was no significant difference in SICS incidence between MPDS (PQ-alexidine=5.6\%, PQ-MAPDA=16.7\%; P=0.08). Polyquaternium-1/alexidine dihydrochloride was associated with significantly fewer symptoms of burning/stinging (9.7±0.6 vs. 9.1±2.2; P=0.03) and self-assessed redness (9.8±0.5 vs. 9.2±1.9; P=0.03) on initial lens insertion. There were no significant differences between MPDS for comfort ratings (P>0.05). CONCLUSION: These short-term clinical results provide an initial indication that PQ-alexidine is associated with fewer symptoms on insertion but no significant difference in ocular comfort compared with PQ-MAPDA. Longer studies are required to provide further evidence. This article was published in Eye Contact Lens and referenced in Journal of Clinical & Experimental Pharmacology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords