alexa Suitability of caspofungin for aerosol delivery: physicochemical profiling and nebulizer choice.
Pharmaceutical Sciences

Pharmaceutical Sciences

Pharmaceutica Analytica Acta

Author(s): WongBeringer A, Lambros MP, Beringer PM, Johnson DL

Abstract Share this page

Abstract BACKGROUND: Aerosolized antifungal therapy is a promising route of drug delivery for pulmonary aspergillosis due to attainment of high localized concentrations. Caspofungin, a new antifungal agent with proven efficacy against invasive aspergillosis, has ideal potential for aerosolization. STUDY OBJECTIVE: To examine in vitro the suitability of caspofungin for aerosol administration by characterizing factors that influence efficacy and airway tolerance of aerosol delivery: physicochemical properties, aerodynamics of drug particles, and efficiency of nebulizing systems. DESIGN: Physicochemical characteristics of caspofungin solutions (10 mg/mL and 30 mg/mL) were analyzed: osmolality, pH, viscosity, and surface tension. A time-of-flight aerosol spectrometer API Aerosizer was used to determine aerosol particle size and distribution. Drug output was quantified by high-performance liquid chromatography assay. Nebulizer efficiency was measured by drug output and respirable fraction (percentage of aerosolized particles with a 1 to 5 mum aerodynamic diameter) and compared among three jet nebulizer/compressor systems: device 1, Micromist (Hudson RCI; Temecula, CA)/Pulmo-Aide (model 5650D; DeVilbiss; Somerset, PA); device 2, Sidestream MS 2400/Envoy model IRC 1192 (Invacare; Elyria, OH); and device 3, Pari LC Star/Proneb Ultra (Pari Respiratory Equipment; Midlothian, VA). MEASUREMENTS AND RESULTS: Caspofungin requires 0.9\% NaCl rather than sterile water as the diluent and addition of 0.3N NaOH buffer to adjust acidity of solutions (pH 6.17 to 6.26) in order to achieve optimal physicochemical properties for airway tolerability (osmolality, 150 to 550 milliosmol per kilogram; chloride ion, 31 to 300 mmol/L; and pH 7.4). The drug output rate increased with higher concentrations of drug solution: device 1, 4.0 mg/min vs 12.5 mg/min; device 2, 5.4 mg/min vs 14.7 mg/min; and device 3, 2.3 mg/min vs 12 mg/min, respectively. The percentage of particles within the respirable range varies depending on device and concentration of drug solutions (10 mg/mL vs 30 mg/mL): device 1, 85\% vs 38\%; device 2, 44\% vs 57\%; and device 3, 83\% vs 93\%, respectively. CONCLUSION: Caspofungin solution with adjustments appears to have physicochemical and aerodynamic characteristics suitable for aerosolization when used with either the Pari LC Star/Proneb Ultra or Micromist/Pulmo-Aide devices. Further in vivo testing is warranted. This article was published in Chest and referenced in Pharmaceutica Analytica Acta

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords