alexa The effect of implant design on insertion torque and immediate micromotion.
Dentistry

Dentistry

Research & Reviews: Journal of Dental Sciences

Author(s): Freitas AC Jr

Abstract Share this page

OBJECTIVES: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. MATERIAL AND METHODS: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (90° cut at the apex, tap design); and (3) Blossom(™) (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 90° by a digital torque gauge. Controlled lateral loads of 10 N followed by increments of 5 up to 100 N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. RESULTS: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (P<0.001) progressively from the Blossom to the fluted to the non-fluted design (M ± standard deviation [SD]=64.1 ± 26.8, 139.4 ± 17.2, and 205.23 ± 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (P<0.001) progressively from the Blossom to the fluted to the non-fluted design (M ± SD=530 ± 57.7, 585.9 ± 82.4, and 782.33 ± 269.4 μm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossom, fluted and non-fluted design groups, respectively. CONCLUSION: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque

This article was published in Clin Oral Implants Res and referenced in Research & Reviews: Journal of Dental Sciences

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords