alexa The effects of an autologous transplant on patterns of regeneration in rat sciatic nerve.
Neurology

Neurology

International Journal of Neurorehabilitation

Author(s): Jenq CB, Coggeshall RE

Abstract Share this page

Abstract Autologous transplants are often used in repair of peripheral nerve injury. Quantitative evaluation of the results of such a transplant is obviously desirable. In previous study, we determined numerical and cytologic parameters of the regeneration that followed transection of rat sciatic nerve, but no transplant was used. This work now serves as a basis for evaluating the use of an autologous transplant in the same transection paradigm. Our procedure is to remove 8 mm of sciatic nerve in the thigh. The removed segment is then put into the center of a silicone tube and the proximal and distal stumps of the severed nerve are placed into the ends of the tube. The data show: (1) a high percentage of successful regenerations; (2) a relatively large nerve in the gap; (3) a typical outer perineurium underlying the epineurium; (4) a well-developed fascicular perineurium; and (5) approximately equal numbers of myelinated and unmyelinated axons in the gap and distal stump. If a transplant is not used there are: (1) a greater number of failures of regeneration; (2) a smaller nerve in the gap; (3) a less well-developed fascicular perineurium; (4) unequal numbers of axons in the gap as compared to the distal stump; and (5) no outer perineurium forms. The presence of a typical outer perineurium after a transplant and its absence if a transplant is not used is probably the most striking cytologic difference between the two paradigms. The equal numbers of axons in the gap and distal stump following regeneration after transplantation presumably indicate that all axons in the gap enter the distal stump without branching or ending blindly, a situation that is presumably beneficial and contrasts with the findings when a transplant is not used. Both paradigms show a remarkable increase in the density of blood vessels in the regenerated nerve in the gap between the two stumps. These findings will serve as a basis for further studies on the mechanisms of peripheral nerve regeneration.
This article was published in Brain Res and referenced in International Journal of Neurorehabilitation

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords