alexa The use of toxic equivalency factor distributions in probabilistic risk assessments for dioxins, furans, and PCBs.
Environmental Sciences

Environmental Sciences

Journal of Bioremediation & Biodegradation

Author(s): Finley BL, Connor KT, Scott PK

Abstract Share this page

Abstract Toxic equivalency factors (TEFs) for 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDFs) and coplanar polychlorinated biphenyl (PCB) congeners have been developed by the World Health Organization (WHO). Each TEF was derived from a range of relative potency (REP) estimates obtained from in vivo and in vitro studies wherein the potency of the congener was evaluated relative to 2,3,7,8-TCDD (or some other appropriate benchmark). For most congeners, the range of REP values spans several orders of magnitude, and the degree of conservatism varies widely among the congeners. Although some TEFs are greater than the maximum REP value, others are less than the minimum. This suggests that the point estimate TEFs introduce a significant amount of variability and uncertainty into the PCB and PCDD/F risk assessment process. The use of REP data distributions, rather than point estimate TEFs, would permit a more informed evaluation of the variability and uncertainty in the attendant risk estimates. Further, a standardized method of choosing a TEF from an REP distribution would ensure a uniform degree of conservatism in the TEF values. In this analysis, distributions of REP values were derived for the coplanar PCBs and 2,3,7,8-substituted PCDD/Fs. There are 936 REP values in the WHO database; the number of values per congener ranges from 1 (1,2,3,7,8,9-HxCDF) to 117 (PCB126). Twenty REP values qualified by WHO as "<" were replaced with one-half the stated value; 65 values qualified as ">" were not used. Fit tests indicate that most distributions are lognormal. Mean, standard deviation, and 50th and 95th percentile values for each REP distribution are presented. In general, the WHO TEFs for the PCDD/Fs are at the upper bound (75th percentile or greater) of the underlying REP distributions, while the PCB TEFs tend to be more representative of the central tendency of the underlying REP distribution. A simplistic weighting scheme that emphasizes long-term in vivo studies suggests that the REP distributions may not be overly sensitive to weighting techniques--that is, the statistical descriptors of the weighted distributions were similar to those of the unweighted distributions. A case study using fish tissue PCB and PCDD/F data suggests that in some settings the use of WHO TEFs may understate upper bound PCB risks relative to PCDD/F risks. A preliminary sensitivity analysis suggests that measurement endpoint, tissue-type and species (or strain) may be significant contributors to the variability and heterogeneity in the underlying REP data for some congeners. Although there are fundamental shortcomings inherent in any TEF scheme, evidence suggests that some form of REP distributions should be used in lieu of or in addition to point estimate TEFs in settings where PCBs and PCDD/Fs are commingled. This article was published in J Toxicol Environ Health A and referenced in Journal of Bioremediation & Biodegradation

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

agrifoodaquavet@omicsonline.com

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

clinical_biochem@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

chemicaleng_chemistry@omicsonline.com

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

environmentalsci@omicsonline.com

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

engineering@omicsonline.com

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

generalsci_healthcare@omicsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

genetics_molbio@omicsonline.com

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immuno_microbio@omicsonline.com

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

omics@omicsonline.com

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

mathematics_physics@omicsonline.com

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

medical@omicsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuro_psychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

pharma@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords