alexa Thermal dose determination in cancer therapy.
General Science

General Science

Journal of Biotechnology & Biomaterials

Author(s): Sapareto SA, Dewey WC

Abstract Share this page

Abstract With the rapid development of clinical hyperthermia for the treatment of cancer either alone or in conjunction with other modalities, a means of measuring a thermal dose in terms which are clinically relevant to the biological effect is needed. A comparison of published data empirically suggests a basic relationship that may be used to calculate a "thermal dose." From a knowledge of the temperature during treatment as a function of time combined with a mathematical description of the time-temperature relationship, an estimate of the actual treatment calculated as an exposure time at some reference temperature can be determined. This could be of great benefit in providing a real-time accumulated dose during actual patient treatment. For the purpose of this study, a reference temperature of 43 degrees C has been arbitrarily chosen to convert all thermal exposures to "equivalent-minutes" at this temperature. This dose calculation can be compared to an integrated calculation of the "degree-minutes" to determine its prognostic ability. The time-temperature relationship upon which this equivalent dose calculation is based does not predict, nor does it require, that different tissues have the same sensitivity to heat. A computer program written in FORTRAN is included for performing calculations of both equivalent-minutes (t43) and degree-minutes (tdm43). Means are provided to alter the reference temperature, the Arrhenius "break" temperature and the time-temperature relationship both above and below the "break" temperature. In addition, the effect of factors such as step-down heating, thermotolerance, and physiological conditions on thermal dose calculations are discussed. The equations and methods described in this report are not intended to represent the only approach for thermal dose estimation; instead, they are intended to provide a simple but effective means for such calculations for clinical use and to stimulate efforts to evaluate data in terms of therapeutically useful thermal units.
This article was published in Int J Radiat Oncol Biol Phys and referenced in Journal of Biotechnology & Biomaterials

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords