alexa Treatment of incontinence after prostatectomy using a new minimally invasive device: adjustable continence therapy.
Surgery

Surgery

Medical & Surgical Urology

Author(s): Hbner WA, Schlarp OM

Abstract Share this page

Abstract OBJECTIVE: To evaluate the safety and efficacy of a new minimally invasive urological implant for incontinence after prostatectomy. PATIENTS AND METHODS: The adjustable continence therapy device (ProACT, Uromedica, Plymouth, MN, USA) consists of two balloons placed via a perineal approach bilaterally at the bladder neck in patients after prostatectomy. Titanium ports, attached via discrete tubing to each balloon, are placed in the scrotum, allowing for separate volume adjustments of the balloons at any time during and after surgery. Changes in a quality-of-life questionnaire (I-QoL), pad usage and a subjective continence grading score were assessed in 117 consecutive men after implanting the Pro-ACT, at baseline and at 1, 3, 6, 12 and 24 months. RESULTS: After a mean (range) follow-up of 13 (3-54) months and with a mean of 3 (0-15) adjustments, 67\% of men were dry, using at most one 'security' pad daily; 92\% were significantly improved, and 8\% showed no improvement. The I-QoL score improved from a median of 34.7 to 66.3 after 2 years (42 men; P < 0.001), the daily pad count decreased from a mean of 6 (1-24)/day to 1 (0-6)/day at 2 years (P < 0.001). Continence achieved at < or = 6 months after implantation through incremental adjustment remained durable at > or = 2 years in most patients. There were complications during and after surgery in 54 patients, mostly minor and decreasing with increasing expertise, primarily reflecting the development and refinement of the new surgical technique and its instrumentation. Re-implantation for complications was required in 32 patients, with a 75\% success rate. CONCLUSIONS: The ProACT peri-urethral prosthesis produces durable outcomes equivalent or better than other minimally invasive treatments for incontinence after prostatectomy. Its unique design allows for easy adjustment after surgery to achieve the desired urethral resistance, with no further surgical intervention, thus allowing for an optimum balance between voiding pressures and continence. The promising results reported here suggest that this may be an appropriate, effective and durable first-line treatment to offer men with stress urinary incontinence after prostatectomy. This article was published in BJU Int and referenced in Medical & Surgical Urology

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords