alexa Ultrasonographically guided peripheral intravenous cannulation in emergency department patients with difficult intravenous access: a randomized trial.
Medicine

Medicine

Emergency Medicine: Open Access

Author(s): Stein J, George B, River G, Hebig A, McDermott D

Abstract Share this page

Abstract STUDY OBJECTIVE: We seek to compare ultrasonographically guided peripheral intravenous access to a non-ultrasonographically guided method in a randomized trial of emergency department patients with difficult intravenous access. METHODS: A prospective cohort of patients with difficult intravenous access was established. Patients were randomized to 2 groups: (1) intravenous access obtained through an ultrasonographically guided technique or (2) intravenous access obtained through non-ultrasonographically guided methods. Outcomes measured were number of attempts after enrollment, time to cannulation from enrollment, and patient satisfaction. Groups were compared with nonparametric analysis. RESULTS: Fifty-nine patients were randomized. Twenty-eight patients were randomized to the ultrasonography group and 31 to the no ultrasonography group. A median of 2 further intravenous attempts was required in each group before successful cannulation, corresponding to a difference of 0 attempts (95\% confidence interval [CI] 0 to 1 attempts). Time to cannulation showed a median of 39 minutes in the ultrasonography group compared with 26 minutes for the no ultrasonography group, giving a median increase of 13 minutes for the ultrasonographically guided group (95\% CI -5 to 28 minutes). Patients in the ultrasonography group had a median Likert satisfaction score of 8 compared with 7 for the no ultrasonography group, giving a median increase of 1 on this scale in the ultrasonography group (95\% CI 0 to 2). CONCLUSION: Ultrasonographically guided peripheral intravenous cannulation did not decrease the number of attempts or the time to successful catheterization, nor did it improve patient satisfaction compared with the group that did not use ultrasonography. Superiority of ultrasonographically guided peripheral intravenous cannulation is not supported by this study. This article was published in Ann Emerg Med and referenced in Emergency Medicine: Open Access

Relevant Expert PPTs

Relevant Speaker PPTs

Recommended Conferences

Relevant Topics

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords