alexa Abstract | A novel validated RP-HPLC-DAD method for the estimation of Lenvatinib Mesylate in bulk and pharmaceutical dosage form

Journal of Chemical and Pharmaceutical Research
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Original Articles Open Access

Abstract

A novel approach was used to develop and validate a rapid, accurate, precise, simple, efficient and reproducible isocratic Reversed Phase-High Performance Liquid Chromatographic (RP-HPLC-DAD) method for the estimation of Lenvatinib Mesylate in bulk and pharmaceutical dosage form. Lenvatinib Mesylate were separated using Kromasil C18 column (250mm×4.6 mm, 5mm particle size), Waters Alliance e2695 HPLC system with 2998 PDA detector and the mobile phase contained a mixture of 0.01M Ammonium acetate (pH adjusted to 3.5 with orthophosphoric acid) and Methanol (30:70, v/v). The flow rate was set to 1ml/min with the responses measured at 309nm. The retention time of Lenvatinib Mesylate was found to be 3.733min.Linearity was established for Lenvatinib Mesylate in the range of 10-125μg/ml with correlation coefficient (r2=0.999). The percentage recoveries were between 100.3% to 100.6%. Validation parameters such as specificity, linearity, precision, accuracy, robustness, limit of detection (LOD) and limit of quantitation (LOQ) were evaluated for the method according to the International Conference on Harmonization (ICH) Q2 R1 guidelines. The developed method was successfully applied for the quantification and hyphenated instrumental analysis.

To read the full article Peer-reviewed Article PDF image

Author(s): Uttam Prasad Panigrahy and A Sunil Kumar Reddy

Keywords

Lenvatinib Mesylate, PDA detector, Hyphenated, ICH, RP-HPLC-DAD method

 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords