alexa Abstract | Appropriate Length of the Central Venous Catheter Insertion via Right Internal Jugular Vein in Children Using External Anatomical.

Current Pediatric Research
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Abstract

A CVC (central venous catheter) is used to measure Central venous pressure and also to administer drugs. The direct measurement of the estimated insertion length using the puncture site and the external landmark could be more practical and bedside. Here we use sternal head of right clavicle and nipple as landmarks for inserting the CVC (central venous catheter) tip near the svc (superior vena cava) and right atrial junction. Objectives of the Study: To Evaluate a method for cvp insertion depth using anatomical landmark

Materials and Methods: A study in PICU, KIMS (kempegowda institute of medical sciences) from Oct 13-14. 35 patients were enrolled irrespective of age. Point A marked at the sternal head of the right clavicle, A horizontal line drawn connecting the nipple on both sides, and then the midpoint of the perpendicular line drawn between Point A and the horizontal line was designated as Point B. The distance between the insertion point of the needle (I) and Point A is measured and the distance between Points A and B was also measured. Insertion depth was determined by adding the two and subtracting 0.5 cm from this. Presence of CVC tip in right atrium and svc junction was confirmed using 2D Echo (echo cardiography) and X-ray chest.

Results: Out of the 35 cases studied in 32 cases cvc was exactly placed at the level of carina (91.4%) and in 3 cases the tip was exactly placed at right atrial and svc junction, while in the rest it was deep. On an average with the above formula one could place a cvc 2.9mm SD =/-1.62 mm deep in the right atrium.

Conclusion: It is inferred that this method can be used safely in calculating length of the CVC for right IJV catheterization.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Murali BH Srividya GS Reshmavathi V

Keywords

Central Venous Catheter, Carina clavicle, Nipple, Sternoclidomastoid, 2D-ECHO., Children

 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords