alexa Abstract | Effect of substituent on working of potentiometric sensors for lanthanum

Advances in Applied Science Research
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

La(III) selective electrodes have been prepared by using 2-Hydroxy-N-(2’-hydroxyphenyl) benzalideneimine (as I) and 5-Bromo-2-hydroxy-N-(2’-hydroxyphenyl) benzalideneimine (as II) as electro active materials and epoxy resin as a binding material. The electrodes were prepared with composition 50% electro active material and 50% binder. An excellent response was shown by (I) in the concentration range of 10-6 M - 10-1 M La (III) ions with a sub Nernstian slope of 14 mV/decade. It has a fast response time of 10 seconds and can be used for at least six months without any considerable potential divergence. The response shown by electrode (II) was also in the concentration range of 10-6 M - 10-1 M La (III) ions with a sub Nernstian slope of 7 mV/decade. It also has a fast response time of 10 seconds and can be used for at least four months without any considerable potential divergence. Effect of internal solution has been studied and the electrodes were successfully used in partially non-aqueous medium, too. Selectivity coefficients have been determined by FIM method, with respect to alkali, alkaline earth, some transition and rare earth metal ions. Electrode (I) can be used in the pH range of 2.85-7.5 and electrode (II) shows pH range of 2.9-8.9. Both the electrodes have been used as indicator electrodes in the potentiometric titration of La (III) ions against Tartaric acid.

To read the full article Peer-reviewed Article PDF image

Author(s): Sharma Harish K Verma Neha and Kapoor J K

Keywords

Selectivity coefficient, Fixed interference method (FIM), Potentiometric titration, (Ion selective electrode) ISE., Potentiometric titration

 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords