alexa Abstract | Evaluation of titanium alloy fabricated using electron beam melting and traditional casting technique

Biomedical Research
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

Purpose: Recent advances in the field of medical industry have encouraged the surgeons and researchers to find alternative ways in the fabrication of implants. The average life of an implant depends on the implant material, its fabrication and patient fixation type.

Approach: Implants produced through casting are of standard shapes and sizes. Moreover, it involves several steps that increase the production cost and time. Alternatively, it is possible to produce custom design implant with Additive manufacturing technology in lesser amount of time with no material wastage.

Objective: The objective of this research is to outline the manufacturing technologies, involved in the fabrication of reconstruction plates and compare the mechanical properties between them.

Finding/Results: The results show a significant difference between the reconstruction plates produced through Electron beam melting (EBM) an additive manufacturing technology and commercial produced casting technique. The EBM produced plates has marginally higher tensile strength of 608 MPa when compared to the commercially available casting plate with the strength of 557 MPa.

Conclusion: The EBM is an effective technology exhibiting favourable results in fabricating customized reconstruction plates with better mechanical properties when compared to traditional fabrication methods. EBM produced implants decreases the implant failure and concomitantly reduces the number of revisions thus eliminating the psychological stress and pain of the patients.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Khaja Moiduddin Abdulrahman AlAhmari Emad S Abouel Nasr Mohammed Al Kindi Mohammed Hamid

Keywords

Electron beam melting, Ti6Al4V ELI, Reconstruction plates, Casting, Mechanical properties, #

 