alexa Abstract | Implication of enterohepatic re-circulation on single dose bioequivalence evaluation of two brands of clonidine hydrochloride tablets in healthy human volunteers

Indian Journal of Pharmaceutical Sciences
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

A single dose, crossover bioequivalence study of two different brands of clonidine hydrochloride 25 μg tablets was conducted in 24 (+2 stand by) healthy, adult, male, Indian subjects under fasting conditions to check the implication of enterohepatic re-circulation on assessment of bioequivalence. After an overnight fasting of at least 10 h, the subjects received single oral dose of test or reference product with either of the product as per randomization schedule in each period with a washout period of 10 days. The pre-dose blood sample was collected within a period of one h before dosing. The post-dose blood samples were collected at specified time intervals up to 96 h. The plasma concentrations of clonidine were quantified by validated LCMS/MS method and pharmacokinetic parameters were computed. The 90% confidence intervals of test/reference ratios for C max and area under the plasma-concentration- time-curve AUC under 0-t were found to be between 0.80 and 1.25 for log-transformed data. Analysis of variance did not show significant difference to these parameters. No meaningful values of K el and therefore AUC under 0-infinity could be calculated for significant number of subjects due to enterohepatic re-circulation. Based on the results obtained, two different brands of clonidine 25 μg tablets have comparable rate and extent of absorption after oral administration but failed to show bioequivalence as per regulatory requirement of Food and Drugs Administration-united states.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): HR Mehta IK Patel NH Patel DM Patel AB Parmar

Keywords

Enterohepatic re-circulation, clonidine hydrochloride, area under curve, analysis of variance, bioequivalence

 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us