alexa Abstract | Repeatability of Oscillometric Determinations of the Ankle-Brachial Index. The Atherosclerosis Risk in Communities (ARIC) Study
ISSN: 2329-9495

Angiology: Open Access
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

Background: The ankle-brachial index (ABI) is a noninvasive and inexpensive means to assess lower extremity artery patency with established validity. Low ABI values are predictive of cardiovascular morbidity and all-cause mortality. Automated, oscillometric devices are commonly used to measure ABI in population studies for time efficiency and to reduce observer-dependent variability. The repeatability of multi-limb systolic blood pressure (SBP) and of ABI using oscillometric devices has not been evaluated in depth. Methods: Two examinations 4-8 weeks apart were conducted on 79 participants using standardized protocols. Using the VP-1000 Plus system bilateral systolic blood pressure (brachial and ankle) and ABI were measured twice five minutes apart, during each examination. The intra-class correlation coefficient (ICC), the corresponding 95% confidence intervals (95% CI), minimal detectable change (MDC95), and minimal detectable difference (MDD) were calculated. Results: The ICCs (95% CI) were 0.62 (0.49, 0.75) for right brachial SBP, 0.65 (0.53, 0.77) for left brachial SBP, 0.61 (0.48, 0.74) for right ankle SBP, 0.66 (0.55, 0.78) for left ankle SBP, 0.48 (0.34, 0.64) for right ABI, and 0.61 (0.48, 0.73) for left ABI. The MDC95 was 0.22 for right ABI, and 0.20 for left ABI. The MDD for two independent samples (N=100) was 0.06 for both right ABI and left ABI. Conclusion: The 4-8 week repeatability measures of the arm and ankle SBP, and of the left ABI are substantial, and the estimated repeatability of the right ABI is moderate. Reliability estimates based on this study can be used to correct for bias when using ABI.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Ada Al-Qunaibet, Michelle L Meyer, David Couper, Hirofumi Tanaka, Susan Cheng, Kunihiro Matsushita, Aaron R Folsom and Gerardo Heiss

Keywords

Repeatability, Reliability, Lower extremity atherosclerotic disease

Share This Page

Additional Info

Loading
Loading Please wait..
 
 
 
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords