Research Article Open Access

Abstract

The development of a solid-phase immunoradiometric assay to satisfy the pressing need for a simple yet effective method for measuring 25-hydroxyvitamin D[25(OH)D] in a serum and thus more suited to routine use in clinical biochemical laboratories[1]. The aim of this study was not to compare our home made with commercially available method but tested for general assay performance, including homemade polyclonal antibody specificity. Methods: We used our home made radioiodine (125I)-based IRMA kit for the detection of 25(OH)D. It is based upon, non-competitive displacement agents which enable effective separation of vitamin D metabolites from binding proteins to enable the amount of vitamin D metabolites to be measured, without competing with the proteins or requiring its solvent extraction from the serum [2,3]. Results: Our package called: “cgea 25(OH)D-irma” is analytically, all qualities we expect from a good medical test kit, with a precision of coefficients below 13% as well as intra-series that in inter-series and inter-batch accuracy with a linearity estimated at 0.8ng/ml and good stability of the radio labeled trace (60 days) [4,5]. Conclusion: Simplification of the methods for extraction and separation has been a key feature in the improvement of assays for vitamin D in Democratic Republic of Congo. However, continuing efforts to improve laboratory performance vigilance with quality assurance programs are required and continuous efforts for improving the reliability of our homemade-test, such as regular internal QC are needed.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Tshiband A, Mputu L, Tozin R, Ingala and Kiampa Philomene M

Keywords

25-hydroxyvitamin D, IRMA, Displacement buffer, Radio iodination, Displacement buffer., Medial Physics,Biomedical Engineering

Share This Page

Additional Info

Loading
Loading Please wait..
 
 
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords