alexa Abstract | The Effect of Pattern Materials on the Marginal Gap of Metal Copings Fabricated On Titanium Implant Abutments
ISSN: 2247-2452

Oral Health and Dental Management
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

Aims: This study was aimed to compare the effect of three different pattern materials on the vertical marginal discrepancy of Nickel-Chromium copings fabricated on titanium implant abutments. Methods: A titanium implant abutment was used to receive 30 Nickel-Chromium copings. The copings were constructed using pattern wax (group 1), acrylic pattern resin (group 2), and lightcured pattern resin (group 3). The marginal gap of the Nickel-Chromium copings was measured at 4 points on the abutmentimplant assembly by using a digital microscope. One-way ANOVA and post hoc tests were adopted for statistical analysis (α=0.05). Results: The mean marginal gap values of Nickel-Chromium copings fabricated from pattern wax, acrylic pattern resin, and lightcured pattern resin were 34.00, 31.78 and 25.87 μm, respectively. There was a statistically significant difference between groups 1 and 3 (p=0.02), whilst the difference between groups 2 and 3 and between groups 1 and 2 was not statistically significant (p>0.05). Conclusions: The marginal gaps of the copings, fabricated from tested pattern materials, were within the clinically acceptable range. Nevertheless, light-cure pattern resin had a better vertical marginal fit than acrylic pattern resin and pattern wax.

To read the full article Peer-reviewed Article PDF image

Author(s): Amir Ali Reza Khaledi, Mitra Farzin, Amir Hassain Fathi, Soheil Pardis

Keywords

Implant abutment, Marginal gap, Metal coping, Pattern wax, Resin pattern materials, Dental Implant

Share This Page

Additional Info

Loading
Loading Please wait..
 
 
 
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords