alexa Abstract | True Angle between Anterior-Posterior Impingement in Total Hip Arthroplasty: Why Common Constrained Cups have to Fail
ISSN: 2229-8711

Global Journal of Technology and Optimization
Open Access

OMICS International organises 3000+ Global Conferenceseries Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ Open Access Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

Open Access Journals gaining more Readers and Citations

700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)

Research Article Open Access

Abstract

Background: Dislocation after total hip arthroplasty is a common complication and partially based on impingement. Questions/purposes: (1) The purpose of this study was to investigate the angle between anterior and posterior impingement in current hip cup designs. (2) Furthermore, the aim was to design a model of an acetabular cup with sparing gaps that match to impact areas. Methods: The range of motion was simulated with Maple R8 software using standard parameters in hip arthroplasty. Afterwards, a preliminary model for an optimized acetabular cup was designed in order to avoid impingement and dislocation. Results: (1) Anterior and posterior areas of impingement were not opposite but twisted by an angle of 108.3°. (2) The two main trajectories of motion were identified and areas with corresponding reductions and elevations were appropriate modified. The improvement resulted in a “bidirectional total hip prosthesis” with a combination of a snapfit acetabular cup and a reduced cup profile. Conclusion: The improvements of the described hip prosthesis are based on a simulation and are most likely to prevent impingement and subsequent dislocation. In addition, simulation with standard implantation parameters resulted in a rotational asymmetric implant design. Clinical relevance: Our data provide evidence that conventional hip cup designs fail to prevent impingement due to (1) The incorrect assumption of diagonally arranged impingement areas and the diagonal arranged sparing gaps (2) The sparing gap design itself that technically is not reducing the rim of the cup but instead only has an elevated coverage relative to the center of motion.

To read the full article Peer-reviewed Article PDF image | Peer-reviewed Full Article image

Author(s): Andrej M. Nowakowski, Sebastian Gehmert, Irène Roesle and Karl-Heinz Widmer

Keywords

Total Hip Arthroplasty , Dislocation , , Impingement, Constrained cup, Bidirectional, image Recognition,Modeling and Simulation

Share This Page

Additional Info

Loading
Loading Please wait..
 
 
 
 
Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords