alexa The Highs and Lows of FAIMS: Predictions and Future Trends for High Field Asymmetric Waveform Ion Mobility Spectrometry | Open Access Journals
ISSN: 2157-7439
Journal of Nanomedicine & Nanotechnology
Like us on:
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

The Highs and Lows of FAIMS: Predictions and Future Trends for High Field Asymmetric Waveform Ion Mobility Spectrometry

Yuriy Zrodnikov and Cristina E. Davis*

Department of Mechanical and Aerospace Engineering, University of California, One Shields Avenue-Davis, CA 95616, USA

*Corresponding Author:
Cristina E. Davis
Department of Mechanical and Aerospace Engineering
University of California, One Shields Avenue-Davis
CA 95616, United States
E-mail: [email protected]

Received Date: May 17, 2012; Accepted Date: May 17, 2012; Published Date: May 19, 2012

Citation: Zrodnikov Y, Davis CE (2012) The Highs and Lows of FAIMS: Predictions and Future Trends for High Field Asymmetric Waveform Ion Mobility Spectrometry. J Nanomed Nanotechol 3:e109. doi:10.4172/2157-7439.1000e109

Copyright: © 2012 Zrodnikov Y, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Nanomedicine & Nanotechnology

Abstract

a

Introduction

High Field Asymmetric waveform Ion Mobility Spectrometry (FAIMS) [1], also known as Differential Mobility Spectrometry (DMS), has evolved as a useful method to separate ionized species in the gaseous phase [2]. All ions have a characteristic mobility value, which depends on the Electric field (E-field) and the surrounding gas mixture. The ion drift velocity is given by the product of the ion mobility and the E-field (v = KE). For low electric fields below approximately 1500 V/cm at atmospheric pressure [3], the mobility coefficient value does not change significantly as the E-field strength is varied. Traditional drift tube Ion Mobility Spectrometry (IMS) devices also operate in this regime. A sample is ionized and propelled through the drift tube using a gradient of electric fields. Only ions with a specific mobility value reach the detector(s) and are measured at corresponding drift times.

If the E-field is increased to the “high” strength regime above 1500 V/cm at atmospheric pressure, the relationship between the ionic mobility coefficient and the ratio of electric field strength to gas number (E/N) becomes uniquely nonlinear for different ions. FAIMS, shown in Figure 1, takes advantage of these phenomena by using a rapidly time-varying electric field which varies from low to high strength [4]. Typical FAIMS devices feature a flow channel which includes two parallel planar or annular electrodes separated by a gap. The electric field is created by applying a waveform between the electrodes: one electrode is grounded while a high-frequency AC square waveform is applied to the other electrode. One cycle of the waveform induces an electric field which is initially high strength, and it is then switched to a low strength field in the opposite direction. The time period of each phase is specified such that the product of the electric field and the time period for which it is applied has a net value of zero over a single cycle. Gas-phase ionized sample species are swept through the drift tube by a constant carrier gas, while the E-field causes them to be displaced orthogonally to the gas flow through the device. Since an ion will have a different mobility in the high and low strength regimes, the ion will have a net displacement toward one of the electrodes over each cycle of the waveform. This displacement is counterbalanced by the application of a DC Compensation Voltage (CV). Each CV value allows ion(s) with that corresponding specific differential mobility to pass through the drift tube and reach the ion detector(s). The CV can also be specified to a value characteristic of a certain ion of interest to achieve an ion filtering regime, or it can be swept across a range to record abundance of all ion species that are present in a sample. Dispersion plots which show ion abundance for scans of CV at different values of the asymmetric waveform amplitude are commonly used to display sampled data. This usually provides extremely unique information for different chemicals, potentially leading to avenues for unique compound identification.

nanomedicine-nanotechnology-faims-overview

Figure 1: FAIMS overview.

Frequently, FAIMS or DMS separation methods can be connected in series with other orthogonal analytical chemistry separation and detection techniques. For example, Gas Chromatography (GC) has been used to pre-separate complex analyte mixtures prior to FAIMS further separation and detection [5-8]. It has been shown that analytes of different categories such as aldehydes, ethers, esters, and alcohols have different retention times in the GC [5]. As components exit the GC column at a certain retention time, they enter the FAIMS drift tube where a range of compensation voltage is scanned. For each analyte, there will be a narrow band of CV values for which ions are able to traverse the drift tube and reach the detector. Ion abundance can be visualized as a 3D plot of compensation voltage and GC retention time. Abundance peaks are directly related to the concentration of a specific analyte in the sample. Multiple data analysis techniques [6,7,9,10] have been used to identify ions and make distinctions by comparing the generated data with that of previously-obtained or calibrated results.

FAIMS and other atmospheric-pressure IMS techniques have also been successfully applied as a pre-filter for Mass Spectrometry (MS) systems [11-14]. An outlet at the end of the drift tube provides a path to the MS system, with pumps along the path to lower the pressure of the ion-carrying gas prior to injection. Ion funneling can be used to focus the flow into a narrow stream for the MS [15]. Cylindrical FAIMS systems offer the advantage of reduced ion loss at the FAIMS/ MS interface [16], however planar geometry with the FAIMS drift tube operating at atmospheric pressure has also been used [13].

Applications

Devices based on IMS have been implemented in many diverse applications. Traditionally IMS has been useful as a method for detecting explosive related compounds, and IMS devices are being widely employed in airports throughout the world [17]. Many explosive compounds form stable negatively-charged ions through ionization at atmospheric pressure, which IMS devices can effectively separate and detect. FAIMS detection of various explosive compounds is extremely specific and sensitive, with an example limit of detection as low as 80 parts-per-trillion (ppt) for 2,4,6-trinitrotoluene (TNT) [18]. In addition to detecting explosives, FAIMS devices have also been used for detecting chemical warfare agents [19] as well as narcotics [20].

Besides defense applications, a number of other studies using FAIMS technology have involved Volatile Organic Compound (VOC) detection and analysis [8]. Also, it has been demonstrated that it is possible to distinguish bacteria via biomarker VOCs produced during active proliferation [6]. Studies have also shown that nonvolatile metabolites in endospores can also be targeted for specific microorganism detection [10,21]. More recent biologically-related studies include health monitoring applications, in attempt to identify compounds in human Exhaled Breath Condensate (EBC) which then can be used to diagnose asthma or Chronic Obstructive Pulmonary Disease (COPD) [22,23]. Further, it was shown that GC/DMS can detect low concentrations of specific analytes even in the presence of a complex background mixture in human EBC [24].

Current GC/DMS research also includes identification of compounds from plants. This approach has been applied to analyze VOCs resulting from biogenic activity [25] by examining gas-phase VOCs in vivo from citrus trees [26]. There is also growing evidence that these technologies can be used for in-field detection of host-response to infection with specific pathogens of interest. The broad range of fields that have benefitted from IMS methods is a result of the technology’s robustness. FAIMS in particular is relatively low-cost, and it can operate in atmospheric pressure using air or a specialty carrier gas. It also offers portability and real time sampling [27], and has the capability to be further scaled down for hand-held point detection systems.

Limitations of Current Technologies

Though IMS and FAIMS technologies have been applied successfully for variety of applications, the current methods still have some technical challenges that remain. One limitation has been difficulty to achieve reproducibility and cross-calibration between different instruments. This is primarily a result of imperfect square waveform generation, which is challenging to implement precisely in electronic systems. In general, RF waveform generators may have slight differences between units, and this can lead to small, but potentially significant, changes in FAIMS operation. Two different instruments may separate ions at slightly different compensation voltages. Each instrument can be independently calibrated, and for some applications this issue may not be significant (e.g. targeted analysis of specific compounds with very unique dispersion plots). However, for most emerging biological applications including metabolomics, this may affect each instrument’s ability to collect and compare data seamlessly across many independent units. The RF waveform generation also draws a reasonably significant amount of power [28] and the waveform generator accounts for a large part of a typical FAIMS system’s packaged size. Other parameters affecting FAIMS devices include the composition of the carrier gas mixture, flow rate [29], and ambient humidity. There is also evidence that certain device geometries may favor specific applications [16], and additional work on that front is likely to take place in upcoming years.

Trends

In the future it is likely that many of these limitations will be resolved. Because FAIMS is capable of operating at atmospheric pressure, it would be beneficial to develop a handheld and portable sensor that is completely portable as a full system. Progress in microfabrication and packaging allows further miniaturization of many system-level components, which also appears to be a promising way to improve overall performance. This may allow for adaptation of a FAIMS-like device for other emerging medical applications as well. Additionally, miniature systems require less power to achieve high strength fields due to closer gap spacing of the electrodes in the drift tube region [30]. It would also potentially allow more precise control over local electric fields, leading to higher sensitivity and lower limits of detection. With continuous progress, it is likely that fully handheld point detectors based on FAIMS will be achieved in the near future.

Acknowledgements

The authors would like to thank Dr. A. Aksenov for his substantial comments on the manuscript and discussions of FAIMS instrumentation platforms. This work was partially supported by several funding agencies. The content of this work is solely the responsibility of the authors and does not necessarily represent the official view of these agencies. Partial support is acknowledged from: UL1 RR024146 from the National Center for Research Resources (NCRR), a component of the National Institutes of Health (NIH), and NIH Roadmap for Medical Research; The Hartwell Foundation, Citrus Research Board, and the Florida Citrus Production Research Advisory Council (FCPRAC).

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Recommended Conferences

Article Usage

  • Total views: 11785
  • [From(publication date):
    July-2012 - Sep 21, 2017]
  • Breakdown by view type
  • HTML page views : 7962
  • PDF downloads :3823
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

[email protected]

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

[email protected]

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
adwords