Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.

Tomo Direct to Deliver Static Angle Tomotherapy Treatments

Pierfrancesco Franco1* and Umberto Ricardi2

1Radiation Oncology Department, Tomotherapy Unit, Ospedale Regionale ‘U. Parini’, AUSL Valle d’Aosta, Aosta, Italy

2Oncology Departments, Radiation Oncology Unit, University of Torino, Turin, Italy

*Corresponding Author:
Pierfrancesco Franco
Radiation Oncology Department
Tomotherapy Unit
Ospedale Regionale ‘U. Parini’
AUSL Valle d’Aosta
Viale Ginevra 3, 11100
Aosta, Italy
Tel: +390-165543420
Fax: +390165543421
E-mail: [email protected]

Received date: November 23, 2012; Accepted date: November 25, 2012; Published date: November 30, 2012

Citation: Franco P, Ricardi U (2012) Tomo Direct to Deliver Static Angle Tomotherapy Treatments. J Nucl Med Radiat Ther 3:e107. doi: 10.4172/2155-9619.1000e107

Copyright: © 2012 Franco P, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Journal of Nuclear Medicine & Radiation Therapy

Radiation Therapy (RT) is a mainstay option for human cancer treatment, as it is employed as single agent or within combined modality approaches, with different timelines and aims (radical, neoadjuvant, adjuvant, palliation) and in almost all anatomic districts [1]. In recent years, significant developments have been introduced in RT planning a delivery, leading to improvements in terms of tumor control and normal tissue avoidance [2]. The Tomotherapy Hi-Art II system (Accuray Inc. , Sunnyvale, CA) is a RT platform able to deliver highly conformal intensity modulated radiotherapy (IMRT) plans within a helical geometry under image guidance (IGRT) [3]. A recent platform upgrade is named TomoDirect and it has been introduced in clinical practice in 2010, as a suitable solution for specific clinical context characterized by particular spatial relationships between target volumes (TVs) and organs at risk (OARs) allowing for beam arrangements constrained to a limited number of directions [4]. Tomotherapy delivers 6MV-IMRT through a rotating fan beam carved by a binary multileaf collimator (MLC), since the ring gantry rotates around the treatment couch as it progresses within the gantry bore across the delivery plane [4]. Beam modulation is obtained by a single row of binary leaves for each projected angle over a rotational interval of 7 degrees, up to a total of 51 projections for each gantry revolution. This approach provides robust conformality, abrupt dose fall off and reliable accuracy. However, since radiation is delivered all around the patient, a larger integral dose might become an issue, with low dose delivery (the so called ‘low dose bath’) to body segments that would only receive scatter radiation with a 3D conformal RT approach. During the optimization process, virtual structures named ‘blocks’ can improve dosimetry precluding radiation from specific volumes Thus, RT delivery is limited to fewer directions with a slender set of beamlets. Since the gantry rotational velocity remains constant, while the number of treatment directions decreases (with more gantry rotations needed to deliver the prescribed dose), this might result in unnecessary prolonged treatment time. Whenever the desired treatment is constrained to a limited number of incoming directions, this planning modality might represent an issue. TomoDirect (TD) combines static gantry positions, concomitant couch translation (along the craniocaudal direction) and MLC modulation. Specifically, while the patient is translated along the superior-inferior direction past the fixed fan beam path during delivery of each treatment field (defined as a fixed gantry angle and jaw width), the beam intensity is modulated by the binary collimator while the pitch (fraction of the jaw opening advanced by the treatment couch per evolution) regulates the degree of modulation in the cranio-caudal direction. Soon after the patient has been treated from one angle, the gantry is rotated to a different beam direction and the patient is again passed through the bore for delivery of the subsequent field. To generate TD plans, the treatment field width, pitch (the TD pitch is defined as the distance of couch travel in centimetres per sinogram projection) and modulation factor represent the metrics parameter to be selected. Subsequently, the dose distribution for each beamlet contributing to TV dose is calculated by a convolution/superposition algorithm. Once the beamlet calculation step is completed, the optimization process begins and an iterative least-squares minimization method is used to optimize the objective function. During the final dose computation the optimized sinogram is converted to the delivery sinogram, accounting for leaf fluence output factors and latency data. A fine calculation grid is usually used both in the optimization and calculation process. The treatment planning software is driven by dose-based objectives, correlated penalties and region of interest-based weighting factors. For TVs, minimum and maximum dose values and corresponding penalties are used in addition to a DVH-based prescription point. OARs objectives are described by maximum dose, DVH-based constraints and related penalties. Quality assurance methods for TD treatment include 2D dose distribution verification or diode arrays-based approaches [5]. TD has been evaluated within dosimetric comparison studies, mainly in the context of breast cancer radiotherapy (whole breast radiation after breast conserving surgery, partial breast irradiation, chest wall and nodal irradiation), but also in Hodgkin’s disease [6-9]. These studies provided sufficient evidence on the physical reliability of the system in the investigated scenarios. Furthermore, a preliminary clinical experience reported on TD implementation for whole breast radiation, segmental bone pain palliation and whole brain radiotherapy [4]. More mature clinical series are needed to validate the static angle tomotherapy approach; however TD seems to be an efficient, reliable and throughput oriented method to be used in selected clinical contexts.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Article Usage

  • Total views: 11762
  • [From(publication date):
    August-2012 - Sep 20, 2018]
  • Breakdown by view type
  • HTML page views : 7981
  • PDF downloads : 3781
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2018-19
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

bornova escort

Datta A

[email protected]

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

[email protected]

1-702-714-7001Extn: 9042

Chemistry Journals

Gabriel Shaw

[email protected]

1-702-714-7001Extn: 9040

Clinical Journals

Datta A

[email protected]

1-702-714-7001Extn: 9037

Engineering Journals

James Franklin

[email protected]

1-702-714-7001Extn: 9042

Food & Nutrition Journals

Katie Wilson

[email protected]

1-702-714-7001Extn: 9042

General Science

Andrea Jason

[email protected]

1-702-714-7001Extn: 9043

Genetics & Molecular Biology Journals

Anna Melissa

[email protected]

1-702-714-7001Extn: 9006

Immunology & Microbiology Journals

David Gorantl

[email protected]

1-702-714-7001Extn: 9014

Materials Science Journals

Rachle Green

[email protected]

1-702-714-7001Extn: 9039

Nursing & Health Care Journals

Stephanie Skinner

[email protected]

1-702-714-7001Extn: 9039

Medical Journals

Nimmi Anna

[email protected]

1-702-714-7001Extn: 9038

Neuroscience & Psychology Journals

Nathan T

[email protected]

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

Ann Jose

[email protected]

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

[email protected]

1-702-714-7001Extn: 9042

 
© 2008- 2018 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version
Leave Your Message 24x7